8

 | 

Regency

®

 U38-10 ULTIMATE Freestanding Gas Stove

 | 

8

installation

IMPORTANT MESSAGE  

SAVE THESE 

INSTRUCTIONS

The ULTIMATE Freestanding Gas Stove must be 

installed in accordance with these instructions. 

Carefully read all the instructions in this manual 

first. Consult the "authority having jurisdiction" to 

determine the need for a permit prior to starting 

the installation.

GENERAL SAFETY  

INFORMATION

1)

  The appliance installation must conform with 

local codes or, in the absence of local codes, 

with the current Canadian or National Gas 

Codes, CAN1-B149 or ANSI-223.1 Installation 

Codes.

2)

  The appliance when installed, must be electri-

cally grounded in accordance with local codes, 

or in the absence of local codes with the current 

National Electrical Code, ANSI/NFPA 70 or CSA 

C22.1 Canadian Electrical Code.

3)

  This appliance is Listed for bedroom  instal-

lations when used with a Listed Millivolt 

Thermostat. Some areas may have further 

requirements, check local codes before instal

-

lation.

4)

  This appliance is Listed for Alcove installations, 

maintain minimum Alcove clearances as fol-

lows, minimum ceiling height of  66",  minimum 

width of 48" and a maximum depth of 36".

 

5)

  This unit is not approved for installation into a 

mobile home.

6)

  See general construction and assembly instruc-

tions. 

7)

  This appliance must be connected to a vent 

and terminate to the outside of the building 

envelope. Never vent to another room or inside 

a building.

8)

  Inspect the venting system annually for block

-

age and any signs of deterioration.   

9)

  Any safety glass removed for servicing must 

be replaced prior to operating the appliance.

10)

 To prevent injury, do not allow anyone who is 

unfamiliar with the operation to use the fireplace.

11)

 Wear gloves and safety glasses for protection 

while doing required maintenance.

12)

 Under no circumstances should this appliance 

be modified. Parts that have to be removed for 

servicing should be replaced prior to operating 

this appliance.

13)

 Installation and any repairs to this appliance 

should be done by a qualified service person. A 

professional service person should be called to 

inspect this appliance annually. Make it a prac

-

tice to have all of your gas appliances checked 

annually.

14)

 Do not strike the glass door.

15)

 Under no circumstances should any solid fuels 

(wood, paper, cardboard, coal, etc.) be used in 

this appliance.

16)

 The appliance area must be kept clear and free 

of combustible materials, (gases and other flam

-

mable vapours and liquids).

17)

 Do not connect this gas appliance to chimney flue 

serving a separate sold-fuel burning appliance.

18)

 WARNING: Operation of this appliance when not 

connected to a properly installed and maintained 

venting system or tampering with the blocked vent 

shutoff system can result in carbon monoxide 

(CO) poisoning and possible death.

19)

 This appliance needs fresh air for safe operation 

and must be installed so there are provisions for 

adequate combustion and ventilation air.

 

INSTALLATION  

CHECKLIST

1) 

Loate your appliance. Refer to the following 

sections: 

 

a. Locating Your Ultimate Gas Stove

 

b. Exterior Vent Termination Locations

 

c. Clearance to Combustibles

 

d. Combustion and Ventilation Air

2) 

Install Louvers.  Refer to the "Louver Installation" 

section.

3) 

Choose a venting option and install accordingly.  

Refer to the following sections where applicable: 

 

a. DV Stove Horizontal Vent Kit

 

     Installation

 

b. Dura-Vent Termination Kit

 

c. Set Vent Restrictors. Refer to "Rigid     

    Pipe Venting Arrangement" section.  

 

d. Converting a Class-A Metal Chimney  

    or Masonry Chimney to a Direct Vent  

    system.

4)

   Install 4-AA batteries into receiver. This will

 

enable operation of appliance manually

 

when in "ON" position.

Emissions from burning  wood or gas could 

contain  chemicals  known  to  the  State  of 

California to  cause cancer, birth defects 

or other reproductive harm.

5)

  Make  gas  connections.  Refer  to  "Gas 

Connection" section. 

 

Test the pilot. Must be as per diagram. Refer 

to "Pilot Adjustment" section.

6)

  If necessary, see the "Conversion from NG to 

LPG" section and "Conversion to Lower BTU 

Rating" section.

7)

  Test Gas Pressure. Refer to "Gas Pipe Pressure 

Testing" section .

8)

  Install standard and optional features.  Refer 

to the following sections where applicable: 

 

a. Log Set

 

b. Front Door

 

c. Wall Thermostat

 

d. Remote Control

 

e. Safety Screen

 

f.  Louver Installation

 

g. 1-AA battery into DC spark box

9)

  Final check.  Refer to the "Final Check" section.

Before leaving this unit with the customer, the 

installer  must  ensure  that  the  appliance  is  firing 

correctly and 

operation fully explained to 

customer

.

This includes:

1)

  Clocking the appliance to ensure the correct 

firing rate (rate noted on label) after burning 

appliance for 15 minutes.

2)

  If required, adjusting the primary air to ensure 

that the flame does not carbon. First allow the 

unit to burn for 15-20 min. to stabilize.

CAUTION: Any alteration to the product that 

causes sooting or carboning that results 

in damage is not the responsibility of the 

manufacturer.

Содержание U38-LP10

Страница 1: ...ther flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone i...

Страница 2: ...e you with all the warmth and charm of a woodstove at the flick of a switch The models U38 NG10 and U38 LP10 of this series has been approved by Warnock Hersey Intertek for both safety and efficiency...

Страница 3: ...t 7 Important Message 8 General Safety Information 8 Clearances to Combustibles 9 Optional Outside Air 9 Draft Hood 10 High Elevation 10 Venting 10 Gas Connection 11 Gas Pipe Pressure Testing 11 Conve...

Страница 4: ...UT OUR PRIOR WRITTEN CONSENT CURRENT REVISION PREVIOUS REVISION PART MAT L ANGULAR INSIDE BEND RADII UNITS IN INCHES DIMENSIONS TOLERANCES UNLESS OTHERWISE STATED SCALE DO NOT PROJECTION 3RD ANGLE MOD...

Страница 5: ...ll e demeure si les r glements locaux le permettent Voir la notice de l utilisateur pour plus de renseignements Cet apparene peut pas tre utilis avec d autres gaz sauf si une trousse de conversion cer...

Страница 6: ...directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT...

Страница 7: ...KEPT CLEAN DUE TO HIGH TEMPERATURES THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES WARNING FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILL VOID YOUR WARRANTY AN...

Страница 8: ...ust be kept clear and free of combustible materials gases and other flam mable vapours and liquids 17 Donotconnectthisgasappliancetochimneyflue serving a separate sold fuel burning appliance 18 WARNIN...

Страница 9: ...a mesh grill at the out side termination Do not remove the knockout CLEARANCES TO COMBUSTIBLES The clearances listed below are MINIMUM dis tances Measure the clearance to both the appli ance and the c...

Страница 10: ...llventingmanufacturer srequirementsand local building codes In cold climates we recom mendtheuseofinsulatedB vent chase andliners For altitudes above 2000 ft we recommend that a minimum flue height of...

Страница 11: ...by local codes Copper may also be used if approved by local codes The gas connection at the valve is 3 8 NPT For minimum and maximum supply pressure see the System Data Table U38 NG10 For 0 to 2000 fe...

Страница 12: ...the pilot cap to expose the pilot orifice 10 Pull off the pilot cap to expose the pilot orifice 11 Unscrew the pilot orifice with the allen key and replace with the LPG pilot orifice in the kit 13 Re...

Страница 13: ...position 5 Remove Rear Log Bracket and slide the Log Bracket Restrictor between Position the Log Bracket Restrictor between the Rear Log Bracket and the burner 6 Remove burner orifice with a 1 2 wrenc...

Страница 14: ...ace Rear Log A 02 65 on the two pins on the rear log support 4 Place the Middle Left Log B 02 56 on the two pins as shown Read the instructions below carefully and refer to the diagrams If logs are br...

Страница 15: ...02 44 8 Place Front Right Log E 02 45 on the two pins as shown 9 Place the lava rock in the area between the left and right logs leaving a space in the middle for log F 02 47 Page 2 of 2 C 02 44 5 Sp...

Страница 16: ...t edge of Log G 02 48 must sit snugly against the bracket Side View G 02 48 E 02 45 F 0 2 4 7 12 Position notch in Front Right Log G 02 48 on Log F 02 47 and push the bottom right edge against the bra...

Страница 17: ...1 FRONT DOOR INSTALLATION packaged separately 1 Open the two side panels 4 The latches should already be at the proper setting If they are too hard or too easy to close you may want to adjust them by...

Страница 18: ...re length Note Preferable if the thermostat is installed on an interior wall Regency offers an optional programmable thermostat but any 250 750 millivolt rated non anticipator type thermostat that is...

Страница 19: ...es and are away from sharp edges CAUTION Labelallwires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation WARNING Electrical Grounding Instructions...

Страница 20: ...ACE 8 Hookupremotereceivertowiremarked receiver which will be located on the bottom of the appli ance This remote control requires coding See remote control instructions for details NOTE This applianc...

Страница 21: ...ause injury or property damage Refer to the owner s information manual provided with this appliance For assistance or additional information consult a qualified installer service agency or gas supplie...

Страница 22: ...or or valve Unit Body Firebox Differenttypesandthicknessesofsteelwillexpand and contract at different rates resulting in some cracking and ticking sounds will be heard throughout the cycling process A...

Страница 23: ...roblem call a qualified service person 4 The appliance and venting system must be inspected before use and at least annually by a qualified field service person to ensure that the flow of combustion a...

Страница 24: ...installation and tear the pipe Do not tear or damage the flex pipe IMPORTANT Disconnect power supply before servicing WARNING Electrical Grounding Instructions This appliance is equipped with a three...

Страница 25: ...n t scratch the paint 2 Undo the four screws holding the control panel in place 3 Disconnect all the receiver wires from the back of the panel and then remove panel You should lay the panel on a soft...

Страница 26: ...8 530 Manual Not available as a replacement part 1 732 929 Safety Screen 2 560 920 Top Bottom Gold Louver Assy 560 921 Top Bottom Brush Nickel Assy 560 922 Top Bottom Black Louver Assy 9 560 055 Fan A...

Страница 27: ...er 68 W840470 Pilot Assembly Gasket 71 730 528 Rear Log Bracket 75 730 935 Log Set 78 730 550 Burner Assembly NG LP 80 260 565 Air Shutter Gear Assembly Female 81 904 565 Hex Key 3 16 AF 84 Air Shutte...

Страница 28: ...730 932 Gold Wrap Door Complete 730 933 Black Wrap Door Complete 730 934 Brushed Nickel Wrap Door Complete 101 846 570 Door Gasket Kit 105 Ceramic Paper 107 936 243 Glass Gasket 111 Door Frame Fibre...

Страница 29: ...Regency U38 10 ULTIMATE Freestanding Gas Stove 29 29 notes...

Страница 30: ...30 Regency U38 10 ULTIMATE Freestanding Gas Stove 30 notes...

Страница 31: ...acement parts and issue credit once the replaced component has been returned to Regency and evalu ated for manufacturer defect The authorized selling dealer is responsible for all in field service wor...

Страница 32: ..._________________________________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Seri...

Отзывы: