operating instructions

COPY OF THE LIGHTING PLATE INSTRUCTIONS 

919-456

A)   

This appliance is equipped with an ignition device which automatically lights the pilot. 

     Do not try to light the pilot by hand.

B)  BEFORE OPERATING

 smell all around the appliance area for gas. Be sure to smell next to the fl oor 

     because some gas is heavier than air and will settle on the fl oor.
       

WHAT TO DO IF YOU SMELL GAS

-  Do not try to light any appliance.

-  Do not touch any electric switch, do  not use any phone in your building.

-  Immediately call your gas supplier from a neighbours phone. Follow the gas supplier’s instructions.

-  If you cannot reach your gas supplier, call the fi re department.

C)   

Do not use this appliance if any part has been under water.  Immediately call a qualifi ed service 

      technician to inspect the appliance and replace any part of the control system and any 

       gas control which has been underwater.

A)  

Cet appareil est muni d’un dispositif d’allumage qui allume automatiquement la veilleuse. 

       Ne tentez pas d’allumer la veilleuse manuellement. 

B)   AVANT DE FAIRE FONCTIONNER

, renifl ez tout autour de l’appareil pour déceler une odeur 

      de gaz.  Renifl ez près du plancher, car certains gaz sont pluslourds que l’air et peuvent        

          

          

      s’accumuler au niveau du sol.

       

QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :

    • Ne pas tenter d’allumer d’appareil

    • Ne touchez à aucun interrupteur; ne pas vous servir des téléphones se trouvant dans le 

      bâtiment.

    • Appelez immédiatement votre fournisseur de gaz depuis un voisin. Suivez les  

      instructions du fournisseur.

    • Si vous ne pouvez rejoindre le fournisseur, appelez le service des incendies

C)   

N’utilisez pas cet appareil s’il a été plongé dansl’eau, même partiellement. Faites inspecter  l’appareil par un tech-

nicien qualifi é et remplacez toute partie du système de contrôle et toute commande qui ont été plongés dans l’eau.

DO NOT REMOVE THIS INSTRUCTION PLATE

TO TURN OFF GAS APPLIANCE

This appliance must be installed in accordance with local codes, if any;

if none, follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or

Natural Gas and Propane Installation Codes, CSA B149.1.

CAUTION:  Hot while in operation. Do not touch. Severe Burns may result. Due to high surface 

temperatures keep children, clothing and furniture, gasoline and other liquids having fl ammable 

vapors  away.  Keep  burner  and  control  compartment  clean.  See  installation  and  operating 

instructions accompanying appliance.

WARNING:  If  you  do  not  follow  these  instructions  exactly,  a  fire  or  explosion  may  result 

causing property damage, personal injury or loss of life. Improper installation, adjustment, 

alteration, service or maintenance can cause injury or property damage. Refer to the owner’s 

information manual provided with this appliance. For assistance or additional information 

consult a qualified installer, service agency or gas supplier.

AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice 

risquede déclencher un incendie ou une explosion entraînant des dommages, des blessures ou 

la mort.

Une installation, d'ajustement, de modifi cation, de service ou d'entretien peut provoquer 

des blessures ou des dommages matériels. Reportez-vous au manuel du propriétaire de 

l'information fournie avec cet appareil. Pour obtenir de l'aide ou des informations supplémen-

taires consulter un installateur qualifi é, une agence de service ou fournisseur de gaz.

Important: If the pilot does not hold, turn pilot knob to "OFF" position. Wait 5 minutes to clear gas. If you 

smell gas - STOP! Follow the safety information above. If you don't smell gas, repeat Steps 1-6. 

1) Push in gas control knob slightly and turn to "PILOT" position.
2) Push in control knob all the way and hold in until the pilot lights up. Continue to hold the control knob in 

for about 20 seconds after the pilot is lit. Release knob.

3) Push in gas control knob slightly and turn to "ON" position.
4) Ensure the receiver is in the remote position. 
5) Press and release the ON/OFF button on the remote handheld transmitter. An audible beep should be 

heard from the receiver. 

6)  The unit will turn on.
Important : Si le pilote ne tient pas, tourner le bouton pilote en position "ARRÊT".  Attendre 5 minutes pour 

effacer du gaz. Si vous avez une odeur de gaz - STOP ! Suivez les consignes de sécurité ci-dessus. Si vous 

n'avez pas une odeur de gaz, répétez les étapes 1 à 6.                

1) Enfoncez légèrement le bouton de réglage du gaz et tournez-le à la position « PILOT » (VEILLEUSE).

2) Enfoncez le bouton de réglage jusqu’au fond et tenez-le jusqu’à ce que la veilleuse s’allume. Tenez le bou-

ton de réglage enfoncé environ 20 secondes après l’allumage de la veilleuse. Relâchez le bouton.

3) Enfoncez légèrement le bouton de réglage et tournez-le à la position « ON » (EN MARCHE).

4)  S’assurer que l’interrupteur mural/récepteur soit en position télécommande. 

5)  Appuyer sur la touche ON/OFF de la télécommande et relâcher. Un bip sonore se fera entendre depuis le 

récepteur

6)  Les fl ammes s’allumeront.

1) 

Press "OFF" on the remote or slide receiver switch from remote to "OFF".

2) 

Turn the gas control knob to the "OFF" position to turn off the pilot.

         Pilot may be shut off during prolonged non use periods to conserve fuel.

1)

 

Appuyez sur le bouton "OFF" sur la télécommande ou sur la diapositive interrupteur récepteur de télé-
commande sur "OFF".

2) 

Mettre le bouton de commande de gaz en position OFF pour éteindre la veilleuse.

         Pour économiser le carburant, éteignez la veilleuse quand l’appareil reste longtemps inutilisé.

LIGHTING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

Содержание U38-LP10

Страница 1: ...ther flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone i...

Страница 2: ...e you with all the warmth and charm of a woodstove at the flick of a switch The models U38 NG10 and U38 LP10 of this series has been approved by Warnock Hersey Intertek for both safety and efficiency...

Страница 3: ...t 7 Important Message 8 General Safety Information 8 Clearances to Combustibles 9 Optional Outside Air 9 Draft Hood 10 High Elevation 10 Venting 10 Gas Connection 11 Gas Pipe Pressure Testing 11 Conve...

Страница 4: ...UT OUR PRIOR WRITTEN CONSENT CURRENT REVISION PREVIOUS REVISION PART MAT L ANGULAR INSIDE BEND RADII UNITS IN INCHES DIMENSIONS TOLERANCES UNLESS OTHERWISE STATED SCALE DO NOT PROJECTION 3RD ANGLE MOD...

Страница 5: ...ll e demeure si les r glements locaux le permettent Voir la notice de l utilisateur pour plus de renseignements Cet apparene peut pas tre utilis avec d autres gaz sauf si une trousse de conversion cer...

Страница 6: ...directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT...

Страница 7: ...KEPT CLEAN DUE TO HIGH TEMPERATURES THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES WARNING FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILL VOID YOUR WARRANTY AN...

Страница 8: ...ust be kept clear and free of combustible materials gases and other flam mable vapours and liquids 17 Donotconnectthisgasappliancetochimneyflue serving a separate sold fuel burning appliance 18 WARNIN...

Страница 9: ...a mesh grill at the out side termination Do not remove the knockout CLEARANCES TO COMBUSTIBLES The clearances listed below are MINIMUM dis tances Measure the clearance to both the appli ance and the c...

Страница 10: ...llventingmanufacturer srequirementsand local building codes In cold climates we recom mendtheuseofinsulatedB vent chase andliners For altitudes above 2000 ft we recommend that a minimum flue height of...

Страница 11: ...by local codes Copper may also be used if approved by local codes The gas connection at the valve is 3 8 NPT For minimum and maximum supply pressure see the System Data Table U38 NG10 For 0 to 2000 fe...

Страница 12: ...the pilot cap to expose the pilot orifice 10 Pull off the pilot cap to expose the pilot orifice 11 Unscrew the pilot orifice with the allen key and replace with the LPG pilot orifice in the kit 13 Re...

Страница 13: ...position 5 Remove Rear Log Bracket and slide the Log Bracket Restrictor between Position the Log Bracket Restrictor between the Rear Log Bracket and the burner 6 Remove burner orifice with a 1 2 wrenc...

Страница 14: ...ace Rear Log A 02 65 on the two pins on the rear log support 4 Place the Middle Left Log B 02 56 on the two pins as shown Read the instructions below carefully and refer to the diagrams If logs are br...

Страница 15: ...02 44 8 Place Front Right Log E 02 45 on the two pins as shown 9 Place the lava rock in the area between the left and right logs leaving a space in the middle for log F 02 47 Page 2 of 2 C 02 44 5 Sp...

Страница 16: ...t edge of Log G 02 48 must sit snugly against the bracket Side View G 02 48 E 02 45 F 0 2 4 7 12 Position notch in Front Right Log G 02 48 on Log F 02 47 and push the bottom right edge against the bra...

Страница 17: ...1 FRONT DOOR INSTALLATION packaged separately 1 Open the two side panels 4 The latches should already be at the proper setting If they are too hard or too easy to close you may want to adjust them by...

Страница 18: ...re length Note Preferable if the thermostat is installed on an interior wall Regency offers an optional programmable thermostat but any 250 750 millivolt rated non anticipator type thermostat that is...

Страница 19: ...es and are away from sharp edges CAUTION Labelallwires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation WARNING Electrical Grounding Instructions...

Страница 20: ...ACE 8 Hookupremotereceivertowiremarked receiver which will be located on the bottom of the appli ance This remote control requires coding See remote control instructions for details NOTE This applianc...

Страница 21: ...ause injury or property damage Refer to the owner s information manual provided with this appliance For assistance or additional information consult a qualified installer service agency or gas supplie...

Страница 22: ...or or valve Unit Body Firebox Differenttypesandthicknessesofsteelwillexpand and contract at different rates resulting in some cracking and ticking sounds will be heard throughout the cycling process A...

Страница 23: ...roblem call a qualified service person 4 The appliance and venting system must be inspected before use and at least annually by a qualified field service person to ensure that the flow of combustion a...

Страница 24: ...installation and tear the pipe Do not tear or damage the flex pipe IMPORTANT Disconnect power supply before servicing WARNING Electrical Grounding Instructions This appliance is equipped with a three...

Страница 25: ...n t scratch the paint 2 Undo the four screws holding the control panel in place 3 Disconnect all the receiver wires from the back of the panel and then remove panel You should lay the panel on a soft...

Страница 26: ...8 530 Manual Not available as a replacement part 1 732 929 Safety Screen 2 560 920 Top Bottom Gold Louver Assy 560 921 Top Bottom Brush Nickel Assy 560 922 Top Bottom Black Louver Assy 9 560 055 Fan A...

Страница 27: ...er 68 W840470 Pilot Assembly Gasket 71 730 528 Rear Log Bracket 75 730 935 Log Set 78 730 550 Burner Assembly NG LP 80 260 565 Air Shutter Gear Assembly Female 81 904 565 Hex Key 3 16 AF 84 Air Shutte...

Страница 28: ...730 932 Gold Wrap Door Complete 730 933 Black Wrap Door Complete 730 934 Brushed Nickel Wrap Door Complete 101 846 570 Door Gasket Kit 105 Ceramic Paper 107 936 243 Glass Gasket 111 Door Frame Fibre...

Страница 29: ...Regency U38 10 ULTIMATE Freestanding Gas Stove 29 29 notes...

Страница 30: ...30 Regency U38 10 ULTIMATE Freestanding Gas Stove 30 notes...

Страница 31: ...acement parts and issue credit once the replaced component has been returned to Regency and evalu ated for manufacturer defect The authorized selling dealer is responsible for all in field service wor...

Страница 32: ..._________________________________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Seri...

Отзывы: