installation

VENTING

This heater is a vented appliance and must be 

connected  to  a  chimney/flue  in  accordance  with 

the installation codes.

Note:  The rear pedestal cover plate is only 

required when outside air is being 

used. If using room air for combustion, 

remove this plate from the back of the 

pedestal.

For your safety this heater is equipped with a vent 

safety switch designed to sense incorrect venting 

and react by shutting down the gas supply. This 

thermally actuated switch is located within the draft 

hood and will detect either a blocked chimney or 

backdraft  condition  where  the  chimney  flow  has 

reversed. If this switch shuts the unit down, it in-

dicates a drafting problem that must be identified 

and rectified without delay - the thermally activated 

switch must  

never

 be bypassed or disconnected as 

a hazardous or deadly condition can result.

Venting Requirements 

A four inch diameter vent is required. B-Vent, Class 

A or Masonry with an approved liner are all accept-

able. For cosmetic or aesthetic purposes 6" outer 

vent can be used as long as an approved inner vent 

is installed. Fasten but do not penetrate the inner 

sleeve of the B-Vent when tightening the screw.

Follow all venting manufacturer’s requirements and 

local building codes. In cold climates, we recom-

mend the use of insulated B-vent, chase, and liners.  

For altitudes above 2000 ft. we recommend that a 

minimum flue height of 12 ft. is used.

Flue Mounting Bracket

Attach the flue mounting bracket with the enclosed 

screw as shown in the diagram.

DRAFT HOOD

This heater has a draft hood built in. It must not 

be altered, obstructed, or blocked in any way, and 

the unit must be installed so that the draft hood 

is in the same atmospheric pressure zone as the 

combustion air inlet to the burner. This heater must 

be properly connected to a venting system. This 

heater is equipped with a vent safety shutoff system.

WARNING: Operation of this heater when not 

connected to a properly installed and maintained 

venting system or tampering with the vent safety 

shutoff system can result in carbon monoxide 

(CO) poisoning and possible death

.

HIGH ELEVATION

The U38-10 is approved in Canada for altitude 0 

ft. to 4500 ft. (CAN/CGA-2.17-M91).  For Natural 

Gas installations above 4500 ft. follow current CAN/

CGA-B149.1.

In U.S.A., for installations above 2000 ft. refer to 

current ANSI  Z223.1  Sc8-8.1.2a  appendix  F,  for 

resizing orifice.

Vent Terminations

Installation into Existing 

Woodstove Flue System

1)

  Clean existing Chimney system.

2)

  Run an approved 4" flex liner or "B" vent into 

existing chimney.

Note:  See the chimney systems manufactur-

er for detailed installation instructions.

6” Decorative 

Collar

Содержание U38-LP10

Страница 1: ...ther flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone i...

Страница 2: ...e you with all the warmth and charm of a woodstove at the flick of a switch The models U38 NG10 and U38 LP10 of this series has been approved by Warnock Hersey Intertek for both safety and efficiency...

Страница 3: ...t 7 Important Message 8 General Safety Information 8 Clearances to Combustibles 9 Optional Outside Air 9 Draft Hood 10 High Elevation 10 Venting 10 Gas Connection 11 Gas Pipe Pressure Testing 11 Conve...

Страница 4: ...UT OUR PRIOR WRITTEN CONSENT CURRENT REVISION PREVIOUS REVISION PART MAT L ANGULAR INSIDE BEND RADII UNITS IN INCHES DIMENSIONS TOLERANCES UNLESS OTHERWISE STATED SCALE DO NOT PROJECTION 3RD ANGLE MOD...

Страница 5: ...ll e demeure si les r glements locaux le permettent Voir la notice de l utilisateur pour plus de renseignements Cet apparene peut pas tre utilis avec d autres gaz sauf si une trousse de conversion cer...

Страница 6: ...directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT...

Страница 7: ...KEPT CLEAN DUE TO HIGH TEMPERATURES THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES WARNING FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILL VOID YOUR WARRANTY AN...

Страница 8: ...ust be kept clear and free of combustible materials gases and other flam mable vapours and liquids 17 Donotconnectthisgasappliancetochimneyflue serving a separate sold fuel burning appliance 18 WARNIN...

Страница 9: ...a mesh grill at the out side termination Do not remove the knockout CLEARANCES TO COMBUSTIBLES The clearances listed below are MINIMUM dis tances Measure the clearance to both the appli ance and the c...

Страница 10: ...llventingmanufacturer srequirementsand local building codes In cold climates we recom mendtheuseofinsulatedB vent chase andliners For altitudes above 2000 ft we recommend that a minimum flue height of...

Страница 11: ...by local codes Copper may also be used if approved by local codes The gas connection at the valve is 3 8 NPT For minimum and maximum supply pressure see the System Data Table U38 NG10 For 0 to 2000 fe...

Страница 12: ...the pilot cap to expose the pilot orifice 10 Pull off the pilot cap to expose the pilot orifice 11 Unscrew the pilot orifice with the allen key and replace with the LPG pilot orifice in the kit 13 Re...

Страница 13: ...position 5 Remove Rear Log Bracket and slide the Log Bracket Restrictor between Position the Log Bracket Restrictor between the Rear Log Bracket and the burner 6 Remove burner orifice with a 1 2 wrenc...

Страница 14: ...ace Rear Log A 02 65 on the two pins on the rear log support 4 Place the Middle Left Log B 02 56 on the two pins as shown Read the instructions below carefully and refer to the diagrams If logs are br...

Страница 15: ...02 44 8 Place Front Right Log E 02 45 on the two pins as shown 9 Place the lava rock in the area between the left and right logs leaving a space in the middle for log F 02 47 Page 2 of 2 C 02 44 5 Sp...

Страница 16: ...t edge of Log G 02 48 must sit snugly against the bracket Side View G 02 48 E 02 45 F 0 2 4 7 12 Position notch in Front Right Log G 02 48 on Log F 02 47 and push the bottom right edge against the bra...

Страница 17: ...1 FRONT DOOR INSTALLATION packaged separately 1 Open the two side panels 4 The latches should already be at the proper setting If they are too hard or too easy to close you may want to adjust them by...

Страница 18: ...re length Note Preferable if the thermostat is installed on an interior wall Regency offers an optional programmable thermostat but any 250 750 millivolt rated non anticipator type thermostat that is...

Страница 19: ...es and are away from sharp edges CAUTION Labelallwires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation WARNING Electrical Grounding Instructions...

Страница 20: ...ACE 8 Hookupremotereceivertowiremarked receiver which will be located on the bottom of the appli ance This remote control requires coding See remote control instructions for details NOTE This applianc...

Страница 21: ...ause injury or property damage Refer to the owner s information manual provided with this appliance For assistance or additional information consult a qualified installer service agency or gas supplie...

Страница 22: ...or or valve Unit Body Firebox Differenttypesandthicknessesofsteelwillexpand and contract at different rates resulting in some cracking and ticking sounds will be heard throughout the cycling process A...

Страница 23: ...roblem call a qualified service person 4 The appliance and venting system must be inspected before use and at least annually by a qualified field service person to ensure that the flow of combustion a...

Страница 24: ...installation and tear the pipe Do not tear or damage the flex pipe IMPORTANT Disconnect power supply before servicing WARNING Electrical Grounding Instructions This appliance is equipped with a three...

Страница 25: ...n t scratch the paint 2 Undo the four screws holding the control panel in place 3 Disconnect all the receiver wires from the back of the panel and then remove panel You should lay the panel on a soft...

Страница 26: ...8 530 Manual Not available as a replacement part 1 732 929 Safety Screen 2 560 920 Top Bottom Gold Louver Assy 560 921 Top Bottom Brush Nickel Assy 560 922 Top Bottom Black Louver Assy 9 560 055 Fan A...

Страница 27: ...er 68 W840470 Pilot Assembly Gasket 71 730 528 Rear Log Bracket 75 730 935 Log Set 78 730 550 Burner Assembly NG LP 80 260 565 Air Shutter Gear Assembly Female 81 904 565 Hex Key 3 16 AF 84 Air Shutte...

Страница 28: ...730 932 Gold Wrap Door Complete 730 933 Black Wrap Door Complete 730 934 Brushed Nickel Wrap Door Complete 101 846 570 Door Gasket Kit 105 Ceramic Paper 107 936 243 Glass Gasket 111 Door Frame Fibre...

Страница 29: ...Regency U38 10 ULTIMATE Freestanding Gas Stove 29 29 notes...

Страница 30: ...30 Regency U38 10 ULTIMATE Freestanding Gas Stove 30 notes...

Страница 31: ...acement parts and issue credit once the replaced component has been returned to Regency and evalu ated for manufacturer defect The authorized selling dealer is responsible for all in field service wor...

Страница 32: ..._________________________________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Seri...

Отзывы: