24
|
Regency
®
U38-10 ULTIMATE Freestanding Gas Stove
|
24
maintenance
PANEL DOOR
1)
Remove the door from the unit and place
on a soft surface to prevent scratching.
2)
Pull out the door gasket.
3)
Remove the nuts holding the glass retainers
in place.
4)
Remove the glass retainers (sides, top and
bottom) and the door catch plate.
5)
Replace the glass.
The glass must have
gasketing around it.
6)
Reverse the previous steps, replace the
retainers and fasten with the nuts but do
not overtighten, as this can break the glass.
Note: the door catch plate fits on top of the
left side retainer.
7)
Put gasket glue on the retainers, but do not
put glue on the screws. Replace the door
gasket, the two ends butt tight together on
the bottom edge of the door.
8)
Replace door on the stove and check the
seal.
5)
Lift fan off of the 2 pins, tip back and pull
through firebox opening. Disconnect the
green ground wire from the left side of the
fan as soon as you can reach it.
To Remove U38-10 Fan:
1)
Unplug or disconnect power source to
stove.
2)
Remove all logs and the rear log support,
then remove the 10 screws holding the ac-
cess panel in place.
3)
Unclip the black and white wires from the
fan motor.
4)
Open both side doors and gently pull the
flex pipe away from the center, otherwise
the fan can catch on the flex pipe during
installation and tear the pipe. Do not tear
or damage the flex pipe.
IMPORTANT
Disconnect power supply
before servicing
WARNING: Electrical Grounding
Instructions This appliance is
equipped with a three pronged
(grounding) plug for your protection
against shock hazard and should
be plugged directly into a properly
grounded three-prong receptacle.
Do not cut or remove the grounding
prong from this plug.
FAN MAINTENANCE
If your fan requires maintenance or replacement,
access to the fan is through the access panel
on the rear wall of the firebox.
Note: The unit MUST NOT be operated
without the fan access panel securely
in place and correctly sealed.
IMPORTANT: These fans collect a lot
of dust from within your home. En-
sure you maintain these fan motors
on a regular basis by vacuuming
out the fan squirrel cages, around
the motor, and around the grills on
the back of the stove.
Wraparound Assembly Door
(same glass retainers as the
Panel Assembly)
Alternate Fan Access:
If the rear access cover is
accessible, it can be removed
to provide access to the fan.
Replacing U38-10 Fan:
Reverse the above steps (1 - 4). If necessary
install a new gasket before replacing the fan
access panel. Make sure the fan wires and the
ground wire are reattached.
EN
G
LI
SH
R
EM
O
TE
TP
TH
TPTH
MOTOR
RECEIVER
FCM-COM
Green
White
Red
Black
(+) (-)
Ground
Green
Neutral
Black
Fan Thermodisc
(Normally Open)
Ground
120V AC
60 Hz
Fan
White
Thermodisc Cage
Live
Thermostat
(Optional)
(Millivolt)
DC
Spark Box
To
Electrode
Lockwasher
Fan
ground
Power
cord
ground
wire
Star
washer
Nut
Nut
#8 Ground Lug
Star
washer
Receiver Hearth Mount
Fan Control Module (FCM)