Regency Fireplace Products U38-LP10 Скачать руководство пользователя страница 20

20

 | 

Regency

®

 U38-10 ULTIMATE Freestanding Gas Stove

 | 

20

operating instructions

FIRST FIRE

The first fire in your stove is part of the paint curing 

process. To ensure that the paint is properly cured, 

it is recommended that you burn your fireplace 

for at least four (4) hours the first time you use 

it with the fan on. When first operated, the unit 

will release an odour caused by the curing of the 

paint, the burning off of any oils remaining from 

manufacturing. Smoke detectors in the house may 

go off at this time. Open a few windows to ventilate 

the room for a couple of hours. 

The glass panel may require cleaning after the 

unit has cooled down.  

DO NOT ATTEMPT TO CLEAN THE 

GLASS WHILE IT IS HOT. 

Note:  When the glass is cold and the appliance 

is lit, it may cause condensation and fog 

the glass. This condensation is normal 

and will disappear in a few minutes as 

the glass heats up.

OPERATING  

INSTRUCTIONS

1)

  Read and understand these instructions before 

operating this appliance.

2)

  Check  to  see  that  all  wiring  is  correct  and 

enclosed to prevent possible shock.

3)

  Check to ensure there are no gas leaks.

4)

  Make  sure  the  glass  in  the  door  frame  is 

properly positioned. Never operate the 

appliance with the glass removed.

5)

  Verify that the venting and cap are unobstructed.

6)

  Verify log placement. If the pilot cannot be 

seen when lighting the unit, the logs have 

been incorrectly positioned.

7)

  The unit should never be turned off, and on 

again without a minimum of a 60 second wait.

During  the  first  few  fires,  a  white  film 

may develop on the glass front as part 

of the curing process. The glass should 

be cleaned

 or the film will bake on and 

become very difficult to remove. Use a 

non-abrasive cleaner and NEVER clean 

the glass while it is hot.

Proflame 

video

DO NOT BURN THE APPLIANCE 

WITHOUT THE GLASS FRONT IN 

PLACE.

8)

   Hook up remote receiver to wire marked 'receiver' 

which will be located on the bottom of the appli-

ance. This remote control requires coding. See 

remote control instructions for details.

NOTE:

 This appliance will operate during power 

outages. Only the fan will not operate until 

power is restored. If the remote batteries in 

both the handheld transmitter or receiver lose 

power, the appliance can still be operated by 

sliding the switch on the receiver switch from 

"Remote" to "ON". To turn on the appliance off 

slide the receiver switch from "ON" to "Remote" 

or "OFF".

IMPORTANT:

 The remote control system sup-

plied with this appliance has several options 

for  starting/operating  the  appliance,  please 

read the remote control operating instructions 

(packed  with  remote  control)  to  understand 

how to operate this remote system. You can 

download remote functions video with the QR 

code below..

LIGHTING  

PROCEDURE

Important: If the pilot does not hold, turn pilot knob 

to "OFF" position. Wait 5 minutes to clear gas. If 

you smell gas - STOP! Follow the safety information 

above. If you don't smell gas, repeat Steps 1-6. 

1

.   Push in gas control knob slightly and turn to  

"PILOT" position.

2

. Push in control knob all the way and hold in 

until the pilot lights up. Continue to hold the 
control knob in for about 20 seconds after the 
pilot is lit. Release knob.

3.

 Push in gas control knob slightly and turn to 

"ON" position.

4

. Ensure the receiver is in the remote position. 

IMPORTANT

Prior to igniting or re igniting 

the pilot, remove the glass 

door. 

Set Switch to 

Remote

Diagram 1

5

. Press and release the ON/OFF button on the 

remote handheld transmitter. An audible beep 
should be heard from the receiver. 

ON/OFF 

Button

6.

 The unit will turn on.

SHUTDOWN  

PROCEDURE

1

.  Press "OFF" on the remote or slide receiver 

switch from remote to "OFF".

2

.  Turn the gas control knob to the "OFF" position 

to turn off the pilot.

         

Pilot may be shut off during prolonged non use 

periods to conserve fuel.

Diagram 2

Remote shown in Manual Mode on Hi

Содержание U38-LP10

Страница 1: ...ther flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone i...

Страница 2: ...e you with all the warmth and charm of a woodstove at the flick of a switch The models U38 NG10 and U38 LP10 of this series has been approved by Warnock Hersey Intertek for both safety and efficiency...

Страница 3: ...t 7 Important Message 8 General Safety Information 8 Clearances to Combustibles 9 Optional Outside Air 9 Draft Hood 10 High Elevation 10 Venting 10 Gas Connection 11 Gas Pipe Pressure Testing 11 Conve...

Страница 4: ...UT OUR PRIOR WRITTEN CONSENT CURRENT REVISION PREVIOUS REVISION PART MAT L ANGULAR INSIDE BEND RADII UNITS IN INCHES DIMENSIONS TOLERANCES UNLESS OTHERWISE STATED SCALE DO NOT PROJECTION 3RD ANGLE MOD...

Страница 5: ...ll e demeure si les r glements locaux le permettent Voir la notice de l utilisateur pour plus de renseignements Cet apparene peut pas tre utilis avec d autres gaz sauf si une trousse de conversion cer...

Страница 6: ...directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT...

Страница 7: ...KEPT CLEAN DUE TO HIGH TEMPERATURES THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES WARNING FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILL VOID YOUR WARRANTY AN...

Страница 8: ...ust be kept clear and free of combustible materials gases and other flam mable vapours and liquids 17 Donotconnectthisgasappliancetochimneyflue serving a separate sold fuel burning appliance 18 WARNIN...

Страница 9: ...a mesh grill at the out side termination Do not remove the knockout CLEARANCES TO COMBUSTIBLES The clearances listed below are MINIMUM dis tances Measure the clearance to both the appli ance and the c...

Страница 10: ...llventingmanufacturer srequirementsand local building codes In cold climates we recom mendtheuseofinsulatedB vent chase andliners For altitudes above 2000 ft we recommend that a minimum flue height of...

Страница 11: ...by local codes Copper may also be used if approved by local codes The gas connection at the valve is 3 8 NPT For minimum and maximum supply pressure see the System Data Table U38 NG10 For 0 to 2000 fe...

Страница 12: ...the pilot cap to expose the pilot orifice 10 Pull off the pilot cap to expose the pilot orifice 11 Unscrew the pilot orifice with the allen key and replace with the LPG pilot orifice in the kit 13 Re...

Страница 13: ...position 5 Remove Rear Log Bracket and slide the Log Bracket Restrictor between Position the Log Bracket Restrictor between the Rear Log Bracket and the burner 6 Remove burner orifice with a 1 2 wrenc...

Страница 14: ...ace Rear Log A 02 65 on the two pins on the rear log support 4 Place the Middle Left Log B 02 56 on the two pins as shown Read the instructions below carefully and refer to the diagrams If logs are br...

Страница 15: ...02 44 8 Place Front Right Log E 02 45 on the two pins as shown 9 Place the lava rock in the area between the left and right logs leaving a space in the middle for log F 02 47 Page 2 of 2 C 02 44 5 Sp...

Страница 16: ...t edge of Log G 02 48 must sit snugly against the bracket Side View G 02 48 E 02 45 F 0 2 4 7 12 Position notch in Front Right Log G 02 48 on Log F 02 47 and push the bottom right edge against the bra...

Страница 17: ...1 FRONT DOOR INSTALLATION packaged separately 1 Open the two side panels 4 The latches should already be at the proper setting If they are too hard or too easy to close you may want to adjust them by...

Страница 18: ...re length Note Preferable if the thermostat is installed on an interior wall Regency offers an optional programmable thermostat but any 250 750 millivolt rated non anticipator type thermostat that is...

Страница 19: ...es and are away from sharp edges CAUTION Labelallwires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation WARNING Electrical Grounding Instructions...

Страница 20: ...ACE 8 Hookupremotereceivertowiremarked receiver which will be located on the bottom of the appli ance This remote control requires coding See remote control instructions for details NOTE This applianc...

Страница 21: ...ause injury or property damage Refer to the owner s information manual provided with this appliance For assistance or additional information consult a qualified installer service agency or gas supplie...

Страница 22: ...or or valve Unit Body Firebox Differenttypesandthicknessesofsteelwillexpand and contract at different rates resulting in some cracking and ticking sounds will be heard throughout the cycling process A...

Страница 23: ...roblem call a qualified service person 4 The appliance and venting system must be inspected before use and at least annually by a qualified field service person to ensure that the flow of combustion a...

Страница 24: ...installation and tear the pipe Do not tear or damage the flex pipe IMPORTANT Disconnect power supply before servicing WARNING Electrical Grounding Instructions This appliance is equipped with a three...

Страница 25: ...n t scratch the paint 2 Undo the four screws holding the control panel in place 3 Disconnect all the receiver wires from the back of the panel and then remove panel You should lay the panel on a soft...

Страница 26: ...8 530 Manual Not available as a replacement part 1 732 929 Safety Screen 2 560 920 Top Bottom Gold Louver Assy 560 921 Top Bottom Brush Nickel Assy 560 922 Top Bottom Black Louver Assy 9 560 055 Fan A...

Страница 27: ...er 68 W840470 Pilot Assembly Gasket 71 730 528 Rear Log Bracket 75 730 935 Log Set 78 730 550 Burner Assembly NG LP 80 260 565 Air Shutter Gear Assembly Female 81 904 565 Hex Key 3 16 AF 84 Air Shutte...

Страница 28: ...730 932 Gold Wrap Door Complete 730 933 Black Wrap Door Complete 730 934 Brushed Nickel Wrap Door Complete 101 846 570 Door Gasket Kit 105 Ceramic Paper 107 936 243 Glass Gasket 111 Door Frame Fibre...

Страница 29: ...Regency U38 10 ULTIMATE Freestanding Gas Stove 29 29 notes...

Страница 30: ...30 Regency U38 10 ULTIMATE Freestanding Gas Stove 30 notes...

Страница 31: ...acement parts and issue credit once the replaced component has been returned to Regency and evalu ated for manufacturer defect The authorized selling dealer is responsible for all in field service wor...

Страница 32: ..._________________________________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Seri...