maintenance

DO NOT USE THIS APPLIANCE IF 

ANY PART HAS BEEN UNDER WA-

TER. IMMEDIATELY CALL A QUALI-

FIED SERVICE TECHNICIAN TO 

INSPECT THE APPLIANCE AND TO 

REPLACE ANY PART OF CONTROL 

SYSTEM AND ANY GAS CONTROL 

WHICH HAS BEEN UNDER WATER.

CAUTION:  ANY SAFETY SCREEN 

OR GUARD REMOVED FOR SER-

VICING AN APPLIANCE MUST BE 

REPLACED PRIOR TO OPERATING 

THE APPLIANCE.

WARNING: CHILDREN AND ADULTS 

SHOULD BE ALERTED TO THE HAZ-

ARDS OF HIGH SURFACE TEMPERA-

TURE AND SHOULD STAY AWAY TO 

AVOID BURNS OR CLOTHING IGNI-

TION.  YOUNG CHILDREN SHOULD 

BE CAREFULLY SUPERVISED WHEN 

THEY ARE IN THE SAME ROOM AS 

THE APPLIANCE.

CLOTHING OR OTHER FLAM-

MABLE MATERIAL SHOULD NOT 

BE PLACED ON OR NEAR THE 

APPLIANCE.

MAINTENANCE  

INSTRUCTIONS

 

1)

  Always shut the valve off before cleaning. For 

relighting, refer to lighting instructions. Keep 

the burner and control compartment clean by 

brushing and vacuuming at least once a year. 

When cleaning the logs, use a soft clean brush 

as the logs are fragile and easily damaged.

2)

  Clean glass (never when unit is hot), appliance, 

louvers, and door with a damp cloth.  Never 

use an abrasive cleaner. The gold louvers 

(and optional gold door) may be scratched if 

abrasives are used to clean them.

 

The heater is finished in a heat resistant paint 

and should only be refinished with heat resist

-

ant paint (not with wall paint). Regency

®

 uses 

StoveBright Paint - Metallic Black #6309.

3)

  Make a  periodic check of burner for proper 

position  and  condition.  Visually  check  the 

flame of the burner periodically, making sure 

the flames are steady; not lifting or floating. 

If there is a problem, call a qualified service 

person. 

4)

  The appliance and venting system must be 

inspected before use, and at least annually, 

by a qualified field service person, to ensure 

that the flow of combustion and ventilation air 

is not obstructed. 

  During the annual service call, the burners 

should be removed from the burner tray and 

cleaned. Replace the embers - do not block 

the pilot or burner ports.

5)

  Keep the area near the appliance clear and 

free from combustible materials, gasoline and 

other flammable 

 

vapours and liquids.

6)

  Verify proper operation after servicing.

LOG REPLACEMENT

The unit should never be used with broken logs. 

Turn off the gas valve and allow the unit to cool 

before opening door to carefully remove the logs. 

The pilot light generates enough heat to burn 

someone. If for any reason a log should need 

replacement, you must use the proper replace-

ment log. The position of these logs must be as 

shown in the diagram under Log Installation.  

Note: Improper positioning of logs may cre-

ate carbon build-up and will alter 

the unit’s performance which is not 

covered under warranty.

DOOR AND GLASS  

GASKET

 

If the door gasket requires replacement use 

7/8" diameter oval door gasket (Part # 846-570). 

The glass requires 5/8" flat glass gasket. See 

your Regency

®

 dealer.

GLASS REPLACEMENT

Your Regency

®

 stove is supplied with high 

temperature, 5 mm Neoceram ceramic glass 

that will withstand the highest heat that your 

unit will produce. In the event that you break 

your glass, purchase your replacement from 

an authorized Regency

®

 dealer only, and follow 

the step-by-step instructions for replacement. 

Never operate your unit with broken glass.

WARNING: Do not operate appliance with 

the glass front removed, cracked or broken. 

Replacement of the glass should be done 

by a licensed or qualified service person.

Содержание U38-LP10

Страница 1: ...ther flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone i...

Страница 2: ...e you with all the warmth and charm of a woodstove at the flick of a switch The models U38 NG10 and U38 LP10 of this series has been approved by Warnock Hersey Intertek for both safety and efficiency...

Страница 3: ...t 7 Important Message 8 General Safety Information 8 Clearances to Combustibles 9 Optional Outside Air 9 Draft Hood 10 High Elevation 10 Venting 10 Gas Connection 11 Gas Pipe Pressure Testing 11 Conve...

Страница 4: ...UT OUR PRIOR WRITTEN CONSENT CURRENT REVISION PREVIOUS REVISION PART MAT L ANGULAR INSIDE BEND RADII UNITS IN INCHES DIMENSIONS TOLERANCES UNLESS OTHERWISE STATED SCALE DO NOT PROJECTION 3RD ANGLE MOD...

Страница 5: ...ll e demeure si les r glements locaux le permettent Voir la notice de l utilisateur pour plus de renseignements Cet apparene peut pas tre utilis avec d autres gaz sauf si une trousse de conversion cer...

Страница 6: ...directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT...

Страница 7: ...KEPT CLEAN DUE TO HIGH TEMPERATURES THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES WARNING FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILL VOID YOUR WARRANTY AN...

Страница 8: ...ust be kept clear and free of combustible materials gases and other flam mable vapours and liquids 17 Donotconnectthisgasappliancetochimneyflue serving a separate sold fuel burning appliance 18 WARNIN...

Страница 9: ...a mesh grill at the out side termination Do not remove the knockout CLEARANCES TO COMBUSTIBLES The clearances listed below are MINIMUM dis tances Measure the clearance to both the appli ance and the c...

Страница 10: ...llventingmanufacturer srequirementsand local building codes In cold climates we recom mendtheuseofinsulatedB vent chase andliners For altitudes above 2000 ft we recommend that a minimum flue height of...

Страница 11: ...by local codes Copper may also be used if approved by local codes The gas connection at the valve is 3 8 NPT For minimum and maximum supply pressure see the System Data Table U38 NG10 For 0 to 2000 fe...

Страница 12: ...the pilot cap to expose the pilot orifice 10 Pull off the pilot cap to expose the pilot orifice 11 Unscrew the pilot orifice with the allen key and replace with the LPG pilot orifice in the kit 13 Re...

Страница 13: ...position 5 Remove Rear Log Bracket and slide the Log Bracket Restrictor between Position the Log Bracket Restrictor between the Rear Log Bracket and the burner 6 Remove burner orifice with a 1 2 wrenc...

Страница 14: ...ace Rear Log A 02 65 on the two pins on the rear log support 4 Place the Middle Left Log B 02 56 on the two pins as shown Read the instructions below carefully and refer to the diagrams If logs are br...

Страница 15: ...02 44 8 Place Front Right Log E 02 45 on the two pins as shown 9 Place the lava rock in the area between the left and right logs leaving a space in the middle for log F 02 47 Page 2 of 2 C 02 44 5 Sp...

Страница 16: ...t edge of Log G 02 48 must sit snugly against the bracket Side View G 02 48 E 02 45 F 0 2 4 7 12 Position notch in Front Right Log G 02 48 on Log F 02 47 and push the bottom right edge against the bra...

Страница 17: ...1 FRONT DOOR INSTALLATION packaged separately 1 Open the two side panels 4 The latches should already be at the proper setting If they are too hard or too easy to close you may want to adjust them by...

Страница 18: ...re length Note Preferable if the thermostat is installed on an interior wall Regency offers an optional programmable thermostat but any 250 750 millivolt rated non anticipator type thermostat that is...

Страница 19: ...es and are away from sharp edges CAUTION Labelallwires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation WARNING Electrical Grounding Instructions...

Страница 20: ...ACE 8 Hookupremotereceivertowiremarked receiver which will be located on the bottom of the appli ance This remote control requires coding See remote control instructions for details NOTE This applianc...

Страница 21: ...ause injury or property damage Refer to the owner s information manual provided with this appliance For assistance or additional information consult a qualified installer service agency or gas supplie...

Страница 22: ...or or valve Unit Body Firebox Differenttypesandthicknessesofsteelwillexpand and contract at different rates resulting in some cracking and ticking sounds will be heard throughout the cycling process A...

Страница 23: ...roblem call a qualified service person 4 The appliance and venting system must be inspected before use and at least annually by a qualified field service person to ensure that the flow of combustion a...

Страница 24: ...installation and tear the pipe Do not tear or damage the flex pipe IMPORTANT Disconnect power supply before servicing WARNING Electrical Grounding Instructions This appliance is equipped with a three...

Страница 25: ...n t scratch the paint 2 Undo the four screws holding the control panel in place 3 Disconnect all the receiver wires from the back of the panel and then remove panel You should lay the panel on a soft...

Страница 26: ...8 530 Manual Not available as a replacement part 1 732 929 Safety Screen 2 560 920 Top Bottom Gold Louver Assy 560 921 Top Bottom Brush Nickel Assy 560 922 Top Bottom Black Louver Assy 9 560 055 Fan A...

Страница 27: ...er 68 W840470 Pilot Assembly Gasket 71 730 528 Rear Log Bracket 75 730 935 Log Set 78 730 550 Burner Assembly NG LP 80 260 565 Air Shutter Gear Assembly Female 81 904 565 Hex Key 3 16 AF 84 Air Shutte...

Страница 28: ...730 932 Gold Wrap Door Complete 730 933 Black Wrap Door Complete 730 934 Brushed Nickel Wrap Door Complete 101 846 570 Door Gasket Kit 105 Ceramic Paper 107 936 243 Glass Gasket 111 Door Frame Fibre...

Страница 29: ...Regency U38 10 ULTIMATE Freestanding Gas Stove 29 29 notes...

Страница 30: ...30 Regency U38 10 ULTIMATE Freestanding Gas Stove 30 notes...

Страница 31: ...acement parts and issue credit once the replaced component has been returned to Regency and evalu ated for manufacturer defect The authorized selling dealer is responsible for all in field service wor...

Страница 32: ..._________________________________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Seri...

Отзывы: