Regency Fireplace Products U38-LP10 Скачать руководство пользователя страница 5

 

Regency

®

 U38-10 ULTIMATE Freestanding Gas Stove

  |     

5

 

 

|

 

5

safety decal

This is a copy of the label that accompanies 

each ULTIMATE Freestanding Gas Stove. We 

have printed a copy of the contents here for your 

review. The safety label is located on the inside 

of the drop down pedestal door. 

NOTE: Regency

®

 units are constantly being 

improved.  Check  the  label  on  the  unit  and  if 

there is a difference, the label on the unit is the 

correct one.

SAFETY LABEL FOR THE U38-10

For the State of Massachusetts, installation and repair must be done by a plumber or gasfitter licensed in the Commonwealth of 

Massachusetts.

For the State of Massachusetts, flexible connectors shall not exceed 36 inches in length.

For the State of Massachusetts, the appliances individual manual shut-off must be a t-handle type valve.

The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm 

with battery back up in the same room where the gas appliance is installed.

Minimum Clearances  to Combustibles 

Degagement minimum des materiaux combustibles:

314

Serial No./No de serie

DO NOT REMOVE THIS LABEL/NE 

PAS ENLEVER CETTE ÉTIQUETTE

 

A  7-1/2"  /190mm

B  6" 

/150mm

E  2"  

/50mm

Min. Ceiling Height from top of unit / Min. Plafond  

Hauteur en haut de l'appareil: 

36" / 914 mm 

Duplicate serial #

Model/Modele

U38-NG10

Model/Modele

U38-LP10

314

This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI 

Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.

This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the 

Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States, or when such a standard 

is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard or ANSI A119.2 ou NFPA 

501C Standard for Recreational Vehicles. For use with Fan Kit # 910-331  

This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, perma-

nently located, manufactured (mobile) home where not prohibited by local codes. See owner's manual for details. 

Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation 

ANSI Z223.1, National Fuel Gas Code ou CSA-B149.1 en vigueur.

Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, 

ou la norme 24 CFR Part 3280, Manufactured Home Construction and Safety Standard. Si ces normes ne sont pas pertinentes, 

utilisez la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard, ou ANSI A119.2 ou NFPA 

501C Standard for Recreational Vehicles.

Cet appareil doit être utilize uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé 

dans une maison préfabriquéo

 mobile (É.-U. seulement) installée à demeure si les règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de 

renseignements. Cet apparene

 

peut pas être utilisé avec d'autres gaz sauf si une trousse de conversion certifi ée est fournie. 

This vented gas fi replace heater is not for use with air fi lters. /Ne pas utiliser de fi ltre à air avec ce foyer au gaz à évacuation

.                                                                                          

For use with glass doors certifi ed with the appliance only. /Pour utilisation uniquement avec les portes en verre certifi ées avec 

l'appareil

                    

VENTED GAS FIREPLACE HEATER - 

NOT FOR USE WITH SOLID FUELS. 

FOYER AU GAZ À ÉVACUATION - NE 

PAS UTILISER AVEC DU COMBUSTIBLE 

SOLIDE

.

Made in Canada / Fabrique au Canada

4001172

Listed:

 VENTED GAS FIREPLACE HEATER / FOYER AU GAZ À ÉVACUATION

Certifi ed for/Certifi ée pour:

 CANADA and U.S.A.

Tested to:

 CAN/CGA-2.17-M91(R2009)

Conforms to:

 ANSI Z21.88-2014

Certifi ed to

:CSA 2.33-2014  

MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE

ELECTRICAL SUPPLY/ALIMENTATION ELECTRIQUE: 

115V_60HZ less than/moins de 2 AMP

FPI Fireplace Products International Ltd. 

Delta, BC, Canada

For Use Only with Barrier (Part #  732-512) 

Follow installation instructions.       

Utiliser uniquement avec l’écran ( n ° 732-512) 

Suivre les instructions d’installation.

ÉQUIPÉ À L'UISINE POUR GAZ NATUREL:

Pression d’alimentation minimum

Pression tubulure d’échappement élevée

Pression tubulure d’échappement basse

Dimensions de l’orifi ce

L'altitude

Débit calorifi que maximum selon

Débit calorifi que minimum selon

Transforme en haute l'altitude Gaz Naturel:

Dimensions de l’orifi ce

L'altitude

Débit calorifi que maximum selon

Débit calorifi que minimum selon

Dimensions de l’orifi ce

Débit calorifi que maximum selon

Débit calorifi que minimum selon

ÉQUIPÉ À L'UISINE POUR GAZ PROPANE:

Pression d’alimentation minimum

Pression tubulure d’échappement élevée

Pression tubulure d’échappement basse

Dimensions de l’orifi ce 

L’altitude

Débit calorifi que maximum selon

Débit calorifi que minimum selon

Dimensions de l’orifi ce

Débit calorifi que maximum selon

Débit calorifi que minimum selon

FACTORY EQUIPPED FOR NATURAL GAS: 

Model U38-NG10

Minimum supply pressure 

5" 

WC/C.E. (1.25kPa)

Manifold pressure High 

3.8"    

WC/C.E. (0.94kPa)

Manifold pressure Low 

1.1" 

WC/C.E. (0.27kPa)

Model U38-NG: Factory Equipped for Altitude 0-2000 ft.

Orifi ce size 

#31 

DMS

Altitude 

0-2000  ft/pi 

(0-610)

Maximum Input 

40,000   Btu/h 

(11.73Kwh)

Minimum Input 

21,000  Btu/h 

(6.15Kwh)

Model U38-NG: Convertible for Altitude 2000-4500 ft.

Orifi ce size 

#33 

DMS

Altitude 

2000-4500ft/pi (610-1370m)

Maximum Input 

36,000   Btu/h 

(10.55Kw)

Minimum Input 

19,000  Btu/h 

(5.57Kwh)

Model U38-NG: Convertible to 30,000 Btu for Altitude 0-4500 ft.

Orifi ce size 

#37 

DMS

Maximum Input 

30,000   Btu/h 

(8.78Kwh)

Minimum Input 

15,000  Btu/h 

(4.39Kwh)

FACTORY EQUIPPED FOR PROPANE GAS: 

Model U38-LP10

Minimum supply pressure 

12" 

WC/C.E. (3.00Kpa) 

Manifold pressure High 

11" 

WC/C.E. (2.74Kpa)

Manifold pressure Low 

2.9" 

WC/C.E. (0.72Kpa)

Orifi ce size 

50 

DMS

Altitude 

0-2,000  ft/pi 

(0-610m)

Maximum Input 

38,000  BTU/h  (11.14Kw/h)

Minimum Input 

20,000  BTU/h  (5.86Kw/h)

Model U38-LP: Convertible to 30,000 Btu for Altitude 0-4500 ft.

Orifi ce size 

#52 

DMS

Maximum Input 

30,000   Btu/h 

(8.78Kwh)

Minimum Input 

15,000  Btu/h 

(4.39Kwh)

919-481

Содержание U38-LP10

Страница 1: ...ther flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone i...

Страница 2: ...e you with all the warmth and charm of a woodstove at the flick of a switch The models U38 NG10 and U38 LP10 of this series has been approved by Warnock Hersey Intertek for both safety and efficiency...

Страница 3: ...t 7 Important Message 8 General Safety Information 8 Clearances to Combustibles 9 Optional Outside Air 9 Draft Hood 10 High Elevation 10 Venting 10 Gas Connection 11 Gas Pipe Pressure Testing 11 Conve...

Страница 4: ...UT OUR PRIOR WRITTEN CONSENT CURRENT REVISION PREVIOUS REVISION PART MAT L ANGULAR INSIDE BEND RADII UNITS IN INCHES DIMENSIONS TOLERANCES UNLESS OTHERWISE STATED SCALE DO NOT PROJECTION 3RD ANGLE MOD...

Страница 5: ...ll e demeure si les r glements locaux le permettent Voir la notice de l utilisateur pour plus de renseignements Cet apparene peut pas tre utilis avec d autres gaz sauf si une trousse de conversion cer...

Страница 6: ...directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT...

Страница 7: ...KEPT CLEAN DUE TO HIGH TEMPERATURES THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES WARNING FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILL VOID YOUR WARRANTY AN...

Страница 8: ...ust be kept clear and free of combustible materials gases and other flam mable vapours and liquids 17 Donotconnectthisgasappliancetochimneyflue serving a separate sold fuel burning appliance 18 WARNIN...

Страница 9: ...a mesh grill at the out side termination Do not remove the knockout CLEARANCES TO COMBUSTIBLES The clearances listed below are MINIMUM dis tances Measure the clearance to both the appli ance and the c...

Страница 10: ...llventingmanufacturer srequirementsand local building codes In cold climates we recom mendtheuseofinsulatedB vent chase andliners For altitudes above 2000 ft we recommend that a minimum flue height of...

Страница 11: ...by local codes Copper may also be used if approved by local codes The gas connection at the valve is 3 8 NPT For minimum and maximum supply pressure see the System Data Table U38 NG10 For 0 to 2000 fe...

Страница 12: ...the pilot cap to expose the pilot orifice 10 Pull off the pilot cap to expose the pilot orifice 11 Unscrew the pilot orifice with the allen key and replace with the LPG pilot orifice in the kit 13 Re...

Страница 13: ...position 5 Remove Rear Log Bracket and slide the Log Bracket Restrictor between Position the Log Bracket Restrictor between the Rear Log Bracket and the burner 6 Remove burner orifice with a 1 2 wrenc...

Страница 14: ...ace Rear Log A 02 65 on the two pins on the rear log support 4 Place the Middle Left Log B 02 56 on the two pins as shown Read the instructions below carefully and refer to the diagrams If logs are br...

Страница 15: ...02 44 8 Place Front Right Log E 02 45 on the two pins as shown 9 Place the lava rock in the area between the left and right logs leaving a space in the middle for log F 02 47 Page 2 of 2 C 02 44 5 Sp...

Страница 16: ...t edge of Log G 02 48 must sit snugly against the bracket Side View G 02 48 E 02 45 F 0 2 4 7 12 Position notch in Front Right Log G 02 48 on Log F 02 47 and push the bottom right edge against the bra...

Страница 17: ...1 FRONT DOOR INSTALLATION packaged separately 1 Open the two side panels 4 The latches should already be at the proper setting If they are too hard or too easy to close you may want to adjust them by...

Страница 18: ...re length Note Preferable if the thermostat is installed on an interior wall Regency offers an optional programmable thermostat but any 250 750 millivolt rated non anticipator type thermostat that is...

Страница 19: ...es and are away from sharp edges CAUTION Labelallwires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation WARNING Electrical Grounding Instructions...

Страница 20: ...ACE 8 Hookupremotereceivertowiremarked receiver which will be located on the bottom of the appli ance This remote control requires coding See remote control instructions for details NOTE This applianc...

Страница 21: ...ause injury or property damage Refer to the owner s information manual provided with this appliance For assistance or additional information consult a qualified installer service agency or gas supplie...

Страница 22: ...or or valve Unit Body Firebox Differenttypesandthicknessesofsteelwillexpand and contract at different rates resulting in some cracking and ticking sounds will be heard throughout the cycling process A...

Страница 23: ...roblem call a qualified service person 4 The appliance and venting system must be inspected before use and at least annually by a qualified field service person to ensure that the flow of combustion a...

Страница 24: ...installation and tear the pipe Do not tear or damage the flex pipe IMPORTANT Disconnect power supply before servicing WARNING Electrical Grounding Instructions This appliance is equipped with a three...

Страница 25: ...n t scratch the paint 2 Undo the four screws holding the control panel in place 3 Disconnect all the receiver wires from the back of the panel and then remove panel You should lay the panel on a soft...

Страница 26: ...8 530 Manual Not available as a replacement part 1 732 929 Safety Screen 2 560 920 Top Bottom Gold Louver Assy 560 921 Top Bottom Brush Nickel Assy 560 922 Top Bottom Black Louver Assy 9 560 055 Fan A...

Страница 27: ...er 68 W840470 Pilot Assembly Gasket 71 730 528 Rear Log Bracket 75 730 935 Log Set 78 730 550 Burner Assembly NG LP 80 260 565 Air Shutter Gear Assembly Female 81 904 565 Hex Key 3 16 AF 84 Air Shutte...

Страница 28: ...730 932 Gold Wrap Door Complete 730 933 Black Wrap Door Complete 730 934 Brushed Nickel Wrap Door Complete 101 846 570 Door Gasket Kit 105 Ceramic Paper 107 936 243 Glass Gasket 111 Door Frame Fibre...

Страница 29: ...Regency U38 10 ULTIMATE Freestanding Gas Stove 29 29 notes...

Страница 30: ...30 Regency U38 10 ULTIMATE Freestanding Gas Stove 30 notes...

Страница 31: ...acement parts and issue credit once the replaced component has been returned to Regency and evalu ated for manufacturer defect The authorized selling dealer is responsible for all in field service wor...

Страница 32: ..._________________________________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Seri...

Отзывы: