48
maintenance
GAS MAINTENANCE - RECOMMENDED ANNUAL ROUTINE
Gas Maintenance
09.14.20
1
920-324
Inspect
•
Pilot assembly
•
Burner
•
Pressure relief gaskets/doors
•
Flue connector gasket if present
•
Door seal
•
Firebox
•
Venting
•
Batteries (remote handheld, remote receiver,
DC sparker, change as needed)
•
Burner media (change as needed)
•
Air shutter setting
•
Wiring
Clean
•
Glass
•
Interior bricks / panels
•
Burner ports & burner air shutter
•
Fan blades
•
Log set
•
Pilot orifices
•
Pilot hood (change as needed)
•
Flame sensor (electronic ignition models)
•
Flame electrode
•
Burner orifice
•
Thermocouple (millivolt models)
•
Thermopile (millivolt models)
Recommended Annual Routine Maintenance for Gas Fireplaces, Stoves and Inserts
In order for your Regency appliance to continue to provide comfort to your home periodic maintenance must be performed to ensure it is
operating at peak efficiency. The items in the list should be checked by a licensed gas service technician during the annual service check.
Your unit may require more frequent maintenance checks if you notice any changes in how it operates. Operational changes to look for
can include, but are not limited to, extended start up time, increased fan noise, residue/carbon build up, white build up on the glass/firebox,
increased operating noise etc. Should any of these or other conditions arise, discontinue use and schedule a service check with your
local licensed gas technician. The list below shows items your licensed service technician will need to check and service at least annually.
Check
•
Voltage on thermocouple/thermopile (mil-
livolt models)
•
Ohms reading on flame sense (electronic
ignition models)
•
Inlet/outlet fuel pressures as per rating plate
•
Voltage/ohms readings on gas valve
•
Ohms reading to on/off switch circuit (Mili-
volt models)
Gas Leak Tests
•
Check main gas line connection to valve
•
Check shut off valve connections
•
Check connection at gas valve outlet
•
Check connection at main burner orifice
•
Check pilot fuel line at valve and at pilot
assembly