Regency
®
CLASSIC™ C34-11 Direct Vent Freestanding Gas Stove | 31
|
31
installation
DURA-VENT
TERMINATION KIT
Planning Your Dura-Vent
Installation
There are two basic types of Dura-Vent Direct
Vent System installations: horizontal termination
and vertical termination. Confirm the maximum
horizontal run and maximum vertical rise from
the Diagrams in "Venting Arrangments" section.
When planning your installation, it will be nec-
essary to select the proper length of vent pipe
for your particular requirements. For horizontal
installations, determine the minimum clearance
from the rear of the unit to the wall. It is also
important to note the wall thickness. (The wall
thimble is suitable for 2 x 4 or 2 x 6 wall construc-
tion.) Select the amount of vertical rise desired
for "vertical-to-horizontal" type installations.
Warning: Always maintain required
clearances (airspaces) to nearby com
-
bustibles to prevent a fire hazard. Do
not fill air spaces with insulation.
The minimum clearance of 1-1/4" (32 mm) is
required between the outer wall of the vent
pipe and nearby combustible surfaces. Be
sure to check the vent termination clearance
requirements from decks, windows, soffits, gas
regulators, air supply inlets and public walkways
as specified in the "Exterior Vent Terminal Loca
-
tions" section and in your local building codes.
To determine the length of vent pipe required
for vertical installations, measure the distance
from the unit flue outlet to the ceiling, the ceiling
thickness, the vertical rise in an attic or second
storey, and allow for sufficient vertical height
above the roof line.
For multi-storey applications, fire stops are
required at each floor level. If an offset is
needed, additional pipe, elbows and supports
will be required.
You will require the following Dura-Vent venting
components with your new CLASSIC Direct Vent
Freestanding Gas Stove. Please review your
product to make sure you have everything you
need. In the event that you are missing any
part, contact your dealer.
Note: These are the minimum components
required. Other parts may be required
for your particular installation. See
"Rigid Pipe Venting Components
List" section.
If installing termination on a siding covered wall,
a vinyl siding standoff or furring strips can be
used in order to ensure that the termination is
not recessed into siding.
The vinyl siding standoff is required for walls
with vinyl siding.
Basic
Horizontal Kit
1 90
o
Elbow
1 Wall Thimble Cover
1 Horiz. Sq. Term. Cap
Alternate Horizontal
Termination Caps
Alternate Horizontal
Riser Vent Terminal
Part# 640-530/P
Alternate Snorkel
Termination Cap
The FPI AstroCap
TM
and FPI Riser Vent terminal are certified for installations using FPI venting systems
as well as Simpson Dura-Vent
®
Direct Vent , American Metal Products Ameri Vent Direct Vent, Security
Secure Vent
®
, Selkirk Direct-Temp. AstroCap
TM
is a proprietary trademark of FPI Fireplace Products
International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson
Dura-Vent Co. Inc.
Содержание C34 Classic
Страница 56: ......
Страница 57: ...Regency CLASSIC C34 11 Direct Vent Freestanding Gas Stove 57 57 notes...
Страница 58: ...58 Regency CLASSIC C34 11 Direct Vent Freestanding Gas Stove 58 notes...
Страница 59: ......