English Instruction Manual TAP / Temperature And Pressure Gauge
20
Set
temperature
unit
- Press [MENU] button
1 sec. to activate selection mode.
- Press [DOWN] button
1 sec. to scroll down to the temperature
unit menu.
- Press [SET] button
1 sec. unit field will flash.
- Press [UP] or [DOWN] button
1 sec. to select temperature unit.
- Press [SET] button
1 sec. to confirm.
- Press [MENU] button
1 sec. to return to main display.
Pairing
-Ensure the distance between the devices is less than 5 meters.
- Ensure TAP CLAMP(S) which shall be paired with TAP pressure
gauge are switched on.
- Ensure TAP pressures gauge is on.
- Press [MENU] button
1 sec. on TAP pressure gauge to activate
selection mode.
- Press [DOWN] button
1 sec. of TAP pressure gauge to scroll
down to the field "T".
- Press [SET] button
1 sec. to start scanning.
Display of TAP pressure gauge shows "Scan…"
Note:
If no device can be found, "No Signal" appears on display before
return to menu.
- If device be found, display shows a list of found TAP CLAMP ID(s).
- Select desired TAP CLAMP ID by pressing [UP] or [DOWN] button
1 sec.
- Press [SET] button
1 sec. to start pairing.
During pairing procedure, display shows " Connect…".
Содержание 4687785