System Reset
If the meter becomes unresponsive or if the display freezes, the Reset Pin
can be used to reset the instrument.
1.
Use a paper clip or any similar small object to press the Reset Pin.
2. After pressing the Reset Pin, power the meter back up by holding the
POWER
button for 2 seconds.
3. If resetting the meter does not resolve the issue, please return the
meter to the nearest authorized REED distributor or authorized
Service Center for repair.
Battery Replacement
When the low battery icon
appears on the LCD, the batteries must
be replaced.
1. Remove the two (2) Phillips screws on the back of the meter directly
located above the top of the kickstand.
2. Remove the battery cover.
3. Replace 6 x "AA" batteries.
4. Secure the battery cover with the two (2) Phillips screws.
Applications
Environmental Monitoring in:
• Schools
• Office buildings
• Greenhouses
• Factories
• Hotels
• Hospitals
• Areas where high levels of carbon dioxide are generated