Your X2 COMBAT camera uses a built-in web server, to allow configuration from any web-browser application. 
For full control and setup; Internet Explorer® v7 to 11 must be used. An ActiveX control will be required to 
install on the computer, to allow full access to all setup and control features via the browser. 

The camera contains the following settings as a factory-default configuration: 

Supported Web 

Browsers 

Internet Explorer v7 to v11 (Preferred) 

Install of Active X component required 

Chrome 

MJPEG stream, basic configuration possible, 

no SD card playback, no PTZ controls 

Firefox 

Basilisk 

Edge 

Opera 

IP Address

 

DHCP/ 192.168.0.120 

Camera will look for DHCP address on boot-

up, if no DHCP present, camera will assign 

itself this fixed IP address. Your computer 

must be set to same IP range to connect to 

the camera (example: 192.168.0.254) 

Stream 1 

H.264, 1920x1080p,25fps, CBR 4Mbps 

H.265 & MJPEG options available 

Stream 2 

H.264, D1, 25fps, CBR, 1.5Mbps 

Stream 3 

H.264, CIF, 25fps, CBR, 256kbps 

ONVIF Port 

80 

Configurable 

RTSP Port 

554 

Login Credentials 

admin/admin 

Camera orientation 

Hanging 

 

Connecting to the camera:

 

Your camera will automatically get an IP address from a DHCP server if one is connected to the network. If not; the camera 
will configure a temporary fixed IP address of 

192.168.0.120

, so you can communicate with it. Your computer must be set to 

operate in the same IP address range in order to connect to the camera. Use 

Internet Explorer

 browser to access the 

camera’s web interface (some features, buttons and settings will not be avail

able using other browsers). 

 

Running Internet Explorer in Administrator mode

 

In order to access the full range of functions and features (such as SD card download/backup), Internet 
Explorer browser must be run in Administrator mode. This is separate to being logged in to Windows as 
an administrator; the Internet Explorer program itself must be forced into running in Administrator mode. 
To do this, right-click over the Internet Explorer icon on the desktop screen: 

 

Left-

click the “

Run as administrator

” option. Internet Explorer will launch normally. 

 

 

Содержание X2 COMBAT Series

Страница 1: ...X2 COMBAT IP PTZ cameras Quick guide on page 4 V2 0 January 2020...

Страница 2: ...as a leading edge precision technology surveillance camera offering superb image quality through 3MP resolution excellent low light performance combined with powerful lighting options X2 COMBAT has b...

Страница 3: ...amera head forwards 13 2 0 Power supply installation and setup 14 2 1 Power supply specifications 14 2 2 Power supply layout 15 2 3 PSU connections 14 2 4 Mains power connections 16 2 5 Fuses 16 2 6 P...

Страница 4: ...am 2 H 264 D1 25fps CBR 1 5Mbps Stream 3 H 264 CIF 25fps CBR 256kbps ONVIF Port 80 Configurable RTSP Port 554 Login Credentials admin admin Camera orientation Hanging Connecting to the camera Your cam...

Страница 5: ...manently in Administrator mode It is possible to run Internet Explorer browser from a desktop shortcut permanently in Administrator mode To do this right click over the Internet Explorer icon and left...

Страница 6: ...o access the web management system otherwise some functions may be unavailable Microsoft Edge and other browsers will not allow full functionality as they do not support Active X plugins Open Internet...

Страница 7: ...d the latest plugins as shown in Fig 2 below when you log in to the web management system for the first time Note The computer must have administrator rights assigned and standard security settings to...

Страница 8: ...a static IP address of 192 168 0 120 This will need to be changed to match the IP address range of your network If you are using a DHCP server on the network X2 COMBAT should request and assign an IP...

Страница 9: ...ill need to connect to the camera using the new IP address now DHCP On by default turn off to set fixed IP address Only enable the DHCP button if you wish the camera to acquire an IP address automatic...

Страница 10: ...ystem should be installed where it cannot be tampered with by unauthorised personnel 6 The products should be securely fastened to a structure of sufficient strength to support it Allowance should be...

Страница 11: ...fitted at all times 1 1 PTZ configuration converting hanging camera to upright camera mode X2 COMBAT can be mounted as a hanging dome or upright PTZ configuration The default configuration is Hanging...

Страница 12: ...rve all appropriate safety precautions local building regulations 4 Ensure the Camera is in the correct orientation see FIG B above EMC Information WARNING THIS IS A CLASS A PRODUCT IF INSTALLED IN A...

Страница 13: ...xings screws and alloy covers at the base of each tilt arm using the supplied Allen key 2 Slightly loosen the two Allen screws on each tilt arm 3 Move both tilt arms forward to STOP 4 Tighten both All...

Страница 14: ...nce to allow the cables to enter Ensure cable glands face downwards at all times and securely tightened All cables should be channelled through the appropriately sized gland holes Only use Redvision s...

Страница 15: ...rnal connections Camera DC supply fuse 3 5A 240VAC Mains supply fuse 3 5A 240V AC Mains input Camera Ethernet data Mains Earth connection crimp tag supplied Ethernet RJ45 socket to network switch Came...

Страница 16: ...connection MUST be used SAFETY ENSURE MAINS INPUT EARTH CONNECTIONS ARE SECURELY STRAIN RELIEVED 2 5 Fuses PCB IDENT MAINS POWER LIVE BROWN 110 230 VAC Connection via 2 way terminal block N NEUTRAL BL...

Страница 17: ...nnections required for the PTZ unit and power supply the maximum specified cable run from the PSU to network hub or switch is 50m For runs above this the camera must be switched to 10Mb s link speed T...

Страница 18: ...olour coding idents as shown in table below for terminating the fly lead in the power supply Camera type WIRE COLOUR SIGNAL PSU Connector Pin Red 24V DC Power P2 24V Black 0V DC Power P2 0V Drain wire...

Страница 19: ...Signal 1 Alarm IN 1 Signal P8 G Alarm IN 1 Ground 2 Alarm IN 2 Signal G Alarm IN 2 Ground 3 Alarm IN 3 Signal P9 G Alarm IN 3 Ground 4 Alarm IN 4 Signal G Alarm IN 4 Ground 2 9 Alarm outputs for alar...

Страница 20: ...a setup Please refer to page 3 of this manual for a quick guide to connecting to the camera Please refer to the online X2 COMBAT Web Setup Guide for a detailed description of settings This guide can b...

Страница 21: ...Noise Reduction 3D Digital Image Enhancement dWDR BLC HLC Defog Digital Image Stabilisation Yes P T Range Pan 360 continuous Tilt 165 Cantilever function gives 180 view range P T Speed Pan 160 sec Ti...

Страница 22: ...t or for the expenses thereof If it is determined that returned product is not defective the buyer shall pay Redvision all costs of handling inspection repairs and transportation at Redvision s then p...

Отзывы: