background image

 

X2 COMBAT Install Guide 2.0

 

18

 

2.7  Umbilical cable connections 

Standard and Alarm models: 

Two types of umbilical cable are supplied, dependent upon the camera model used. The Standard 
camera uses a 7-pin Amphenol connector, the Alarm model uses a 14-pin Amphenol connector, 
with additional wires for the alarm signals. The wiring table below covers both types of 
connectors. Each function is clearly labelled on the circuit board, below the appropriate 
connection.

 

 

The wires terminate in the following connector blocks on the PSU circuit board: 

 

 

 

 

 

 

 

 

 

 

 

 

 

Follow the colour coding idents as shown in table below for terminating the fly lead in the 
power supply: 

 

 

 

 

 

Camera type 

WIRE COLOUR

 

SIGNAL

 

PSU 

Connector 

Pin 

 

Red 

24V DC Power 

P2 

+24V 

 

Black 

0V DC Power 

P2 

0V 

 

Drain wire  

Camera chassis Earth 

P2 

GND 

Standard Model 

White/Orange 
 

Camera Rx+ Ethernet 

P3 

RXP 

 

Orange 
 

Camera Rx- Ethernet 

P3 

RXN 

 

White/Blue 

Camera Tx+ Ethernet 
 

P3 

TXP 

 

Blue 

Camera Tx- Ethernet 

P3 

TXN 

 

White/Red 

Alarm IN 1 

P5 

Alarm Model

 

White/Yellow 

Alarm IN 2 

P5 

(in addition to above) 

White/Grey 

Alarm IN 3 

P5 

 

White/Black 

Alarm IN 4 

P5 

 

Pink 

Alarm OUT 1 

P7 

 

Green 

Alarm OUT 2 (Wash relay) 

P7 

 

Power connections 

Ethernet data connections

 

P2

 

P3

 

 

Power & Data connections

 

Power & Data connections

 

Camera Alarm Input connections

 

Camera Alarm Output connections

 

 

P5

 

P7

 

Содержание X2 COMBAT Series

Страница 1: ...X2 COMBAT IP PTZ cameras Quick guide on page 4 V2 0 January 2020...

Страница 2: ...as a leading edge precision technology surveillance camera offering superb image quality through 3MP resolution excellent low light performance combined with powerful lighting options X2 COMBAT has b...

Страница 3: ...amera head forwards 13 2 0 Power supply installation and setup 14 2 1 Power supply specifications 14 2 2 Power supply layout 15 2 3 PSU connections 14 2 4 Mains power connections 16 2 5 Fuses 16 2 6 P...

Страница 4: ...am 2 H 264 D1 25fps CBR 1 5Mbps Stream 3 H 264 CIF 25fps CBR 256kbps ONVIF Port 80 Configurable RTSP Port 554 Login Credentials admin admin Camera orientation Hanging Connecting to the camera Your cam...

Страница 5: ...manently in Administrator mode It is possible to run Internet Explorer browser from a desktop shortcut permanently in Administrator mode To do this right click over the Internet Explorer icon and left...

Страница 6: ...o access the web management system otherwise some functions may be unavailable Microsoft Edge and other browsers will not allow full functionality as they do not support Active X plugins Open Internet...

Страница 7: ...d the latest plugins as shown in Fig 2 below when you log in to the web management system for the first time Note The computer must have administrator rights assigned and standard security settings to...

Страница 8: ...a static IP address of 192 168 0 120 This will need to be changed to match the IP address range of your network If you are using a DHCP server on the network X2 COMBAT should request and assign an IP...

Страница 9: ...ill need to connect to the camera using the new IP address now DHCP On by default turn off to set fixed IP address Only enable the DHCP button if you wish the camera to acquire an IP address automatic...

Страница 10: ...ystem should be installed where it cannot be tampered with by unauthorised personnel 6 The products should be securely fastened to a structure of sufficient strength to support it Allowance should be...

Страница 11: ...fitted at all times 1 1 PTZ configuration converting hanging camera to upright camera mode X2 COMBAT can be mounted as a hanging dome or upright PTZ configuration The default configuration is Hanging...

Страница 12: ...rve all appropriate safety precautions local building regulations 4 Ensure the Camera is in the correct orientation see FIG B above EMC Information WARNING THIS IS A CLASS A PRODUCT IF INSTALLED IN A...

Страница 13: ...xings screws and alloy covers at the base of each tilt arm using the supplied Allen key 2 Slightly loosen the two Allen screws on each tilt arm 3 Move both tilt arms forward to STOP 4 Tighten both All...

Страница 14: ...nce to allow the cables to enter Ensure cable glands face downwards at all times and securely tightened All cables should be channelled through the appropriately sized gland holes Only use Redvision s...

Страница 15: ...rnal connections Camera DC supply fuse 3 5A 240VAC Mains supply fuse 3 5A 240V AC Mains input Camera Ethernet data Mains Earth connection crimp tag supplied Ethernet RJ45 socket to network switch Came...

Страница 16: ...connection MUST be used SAFETY ENSURE MAINS INPUT EARTH CONNECTIONS ARE SECURELY STRAIN RELIEVED 2 5 Fuses PCB IDENT MAINS POWER LIVE BROWN 110 230 VAC Connection via 2 way terminal block N NEUTRAL BL...

Страница 17: ...nnections required for the PTZ unit and power supply the maximum specified cable run from the PSU to network hub or switch is 50m For runs above this the camera must be switched to 10Mb s link speed T...

Страница 18: ...olour coding idents as shown in table below for terminating the fly lead in the power supply Camera type WIRE COLOUR SIGNAL PSU Connector Pin Red 24V DC Power P2 24V Black 0V DC Power P2 0V Drain wire...

Страница 19: ...Signal 1 Alarm IN 1 Signal P8 G Alarm IN 1 Ground 2 Alarm IN 2 Signal G Alarm IN 2 Ground 3 Alarm IN 3 Signal P9 G Alarm IN 3 Ground 4 Alarm IN 4 Signal G Alarm IN 4 Ground 2 9 Alarm outputs for alar...

Страница 20: ...a setup Please refer to page 3 of this manual for a quick guide to connecting to the camera Please refer to the online X2 COMBAT Web Setup Guide for a detailed description of settings This guide can b...

Страница 21: ...Noise Reduction 3D Digital Image Enhancement dWDR BLC HLC Defog Digital Image Stabilisation Yes P T Range Pan 360 continuous Tilt 165 Cantilever function gives 180 view range P T Speed Pan 160 sec Ti...

Страница 22: ...t or for the expenses thereof If it is determined that returned product is not defective the buyer shall pay Redvision all costs of handling inspection repairs and transportation at Redvision s then p...

Отзывы: