![Redline RDL-3000 SC Скачать руководство пользователя страница 40](http://html.mh-extra.com/html/redline/rdl-3000-sc/rdl-3000-sc_user-manual_1429320040.webp)
RDL-3000
User Manual
70-00158-01-DRAFT
Proprietary Redline Communications © 2010
Page
40
of 142
November 25, 2010
Use the following steps to establish a Web session with the RDL-3000.
1.
The IP address and subnet mask of the PC must be on the same subnet as the RDL-
3000. For example:
IP address =
192.168.25.11
Net Mask =
255.255.255.0
2. On the PC, open a browser and enter the unit RDL-3000 IP address. The factory default IP
address is 192.168.25.2.
3. Enter the username and password to login. The factory default username is 'admin', and the
default password is 'admin'.
Fig. 25: Web - Login Screen
4. If the login was successful, the General Information screen will be displayed in the Web
browser.