Wait approximately 75 seconds, then press the ENTER key on the PC to start the
Telnet session. When the login prompt appears, you have a window of 30 seconds to
login using the default username (admin) and password (admin).
If a login prompt does not appear, re-enter the Telnet command during the 30
second interval. If this is not successful, repeat steps 1 to 4 using an initial wait time
of 70 to 90 seconds).
Logging in to the unit immediately restores the admin and user accounts to factory
default usernames and login values, and deletes all other user accounts. No other
parameters are changed. All standard configuration commands are now available to
the operator. If the IP was unknown, this can be now displayed and/or changed.
If the operator does not login during this step, the RDL-3000 reboots automatically
after 30 seconds and is operational after an additional 75 seconds.
6.
Modify settings as required and reboot the RDL-3000 to exit from long reset mode.
Web
If using a web browser to access the RDL-3000, prepare the PC for by opening a Web
browser on the PC and typing the following URL into the address bar:
http
:
//192.168.25.2
Follow the steps for 'Long Reset Using Telnet', substituting the Web browser for Telnet.
6.5.2
Restore Default Passwords Only
Use this procedure if the unit IP address is known and it is desired only to restore the
default usernames and passwords. All other configuration settings are preserved.
Telnet
1.
Perform a long reset and use Telnet to login to the RDL-3000 using the default IP
address (192.168.25.2), and the default administrator username (admin) and
password (admin).
2.
Enter the command
reboot
to restart the unit. Do not enter any other commands.
3.
Login to the RDL-3000 using the user-configured IP address and the default
administrator username (admin) and password (admin).
Web
1.
Perform a long reset and use a Web browser to login to the RDL-3000 using the
default IP address (192.168.25.2), and the default administrator username (admin)
and password (admin).
2.
Click
Configuration->System
to display the
System Configuration
screen.
3.
Click on the
Reboot
buttons at the bottom of the screen to reboot the RDL-3000.
4.
Login to the RDL-3000 using the user-configured IP address and the default
administrator username and password (admin/admin).
6.5.3
Restore Factory Configuration
Use the following steps to restore the RDL-3000 to the factory configuration
Telnet
1.
Perform a long reset and use Telnet to login to the RDL-3000 using the default IP
address (192.168.25.2), and the default administrator username (admin) and
password (admin).
2.
Enter the command
save defaultconfig
. The RDL-3000 will automatically reboot.