Table 38
:
Diag. - Factory Default Settings
CLI Parameter
Web Field
Option
Key
Def Cfg Button Setting
maxtxpower
Maximum Tx Power
14 dBm
optionskey
Options Key
No change
radius
RADIUS
Disabled
ulcir
Service UL CIR
500
ulpir
Service UL PIR
50 000
ulpir
Service UL PIR
50 000
user
Users Management
screen
user/password:
admin / admin
2
x509auth
X.509 Authentication
Off
1. SNMP v2 only in PMP mode; 2. All user-created accounts are deleted.
6.5
Long Reset (Recover from Lost Password or IP)
If the operator can not access the RDL-3000 management interface (forgotten IP,
username, and/or password), a long reset operation must be performed to provide
access the unit. The long reset provides an opportunity to login to the RDL-3000 using
the default IP, usernames and passwords. The long reset procedure requires local
access to the RDL-3000 PoE adapter to power-cycle the RDL-3000, and a PC with an
Ethernet cable and a Telnet client or Web browser.
Fig. 63
:
Diag. - Recovering Lost IP Address
6.5.1
Long Reset Using Telnet
Use the following steps to gain access to the RDL-3000 management interface. It is
recommended to use a clock display on the PC to ensure accurate timing.
Telnet
1.
Power-off the RDL-3000 PoE adapter and remove the local network Ethernet cable.
Use an Ethernet jumper cable to connect the PC directly to the PoE adapter DATA
(INPUT) Ethernet port. Prepare the PC for Telnet access by opening a command
prompt window on the PC and typing the following command (do not press the Enter
key until step 6):
telnet 192.168.25.2
2.
Restore power to the RDL-3000 PoE adapter and wait 10 seconds.
3.
Power-off the RDL-3000 PoE adapter for 5 seconds.
4.
Restore power to the RDL-3000 PoE adapter.