![Redline RDL-3000 SC Скачать руководство пользователя страница 121](http://html.mh-extra.com/html/redline/rdl-3000-sc/rdl-3000-sc_user-manual_1429320121.webp)
RDL-3000
User Manual
70-00158-01-DRAFT
Proprietary Redline Communications © 2010
Page
121
of 142
November 25, 2010
6.3.2
Test Configuration Changes
The operator can use the reboot and apply functions to test changes to the configuration
that may result in loss of the wireless link. Use the following steps to test new setup
values for a five minute period and then restore the last saved configuration.
1. Make all necessary editing changes to the configuration.
2. Issue the command 'reboot 300'. This will set a timer to reboot the RDL-3000 in five
minutes (5 x 60 seconds). A longer or shorter time can also be specified.
3. Issue the 'apply' command to activate all edited changes.
4. If connectivity to the RDL-3000 is lost, wait 5 minutes for the unit to reboot
automatically and restore the previous settings.
5. If the setting are satisfactory, use 'save config' to save these settings and 'reboot 0'
to cancel the timed reboot operation.
6.4
Factory Default Settings
Use the Web interface (click Factory Defaults in main menu) or the CLI interface (save
defaultconfig) to restore the RDL-3000 to a known state.
Table 38
:
Diag. - Factory Default Settings
CLI Parameter
Web Field
Option
Key
Def Cfg Button Setting
System
syscontact
System Contact
Blank
sysdescr
System Details
Blank
sysloc
System Location
Blank
sysname
System Name
RDL-3000
Ethernet
ethmode
Ethernet Mode
Auto
gateway
Default Gateway Address
192.168.25.1
gmt
Time Offset
+0.00
http
HTTP Enable
On
https
HTTPS Enable
N/C
ipaddr
IP Address
192.168.25.2
mgmtag
Mgmt Tag Enable
Off
mgmvid
Mgmt VID
0
netmask
IP Subnet Mask
255.255.255.0
snmp
SNMP
V2
snmpcommunity
SNMP Community
Strings
"Public". read
"Private" read/write
snmptraplink
SNMP Traps
Off
snmptraplist
SNMP Trap List
Cleared
snmptraps
SNMP Trap Links
Off
snmpversion
SNMP Version
V2 (if SNMP enabled)
1
sntp
SNTP Enable
N/C