Safety & Service Notices
1.1
Safety Warnings
1.
Lightning/Surge Protection and Grounding
WARNING to Service Personnel
The system must be installed by a professional installer who is familiar with
both data network issues and RF installations including grounding and surge
protection.
The system must be properly grounded to protect against power surges and
accumulated static electricity. It is the user’s responsibility to install this device
in accordance with the local electrical codes: correct installation procedures for
grounding of the modem, mast, lead-in wire and line protection, location of line
protection, size of grounding conductors and connection requirements for
grounding electrodes.
PoE power adapter caution:
Warning to Service Personnel: 48 VDC
Customer equipment including personal computers, routers, etc., must be connected
only to the INPUT (DATA) port on the PoE unit.
Only the outdoors Ethernet interface cable connecting to the unit can be safely
connected to the OUTPUT (DATA & POWER) connector. Connecting customer
premises Ethernet equipment directly to the OUTPUT (DATA & POWER) connector
on the Power-over-Ethernet power adapter may damage customer equipment.
2. Installation of the system must be contracted to a professional installer.
3. Read this user manual and follow all operating and safety instructions.
4. Keep all product information for future reference.
5. The power requirements are indicated on the product-marking label. Do not exceed the
described limits.
6. Disconnect the power before cleaning. Use only a damp cloth for cleaning. Do not use liquid
or aerosol cleaners.
7. Disconnect power when unit is stored for long periods.
8. The unit must not be located near power lines or other electrical power circuits.
9. The system must be properly grounded to protect against power surges and accumulated
static electricity. It is the user’s responsibility to install this device in accordance with the local
electrical codes: correct installation procedures for grounding the unit, mast, lead-in wire and
discharge unit, location of discharge unit, size of grounding conductors and connection
requirements for grounding electrodes.