3.5
Step 5: Install Indoor PoE Power Block
The PoE adapter provides operational power and the Ethernet connection to the
wireless interface. The power block provides two Ethernet interfaces:
INPUT
(DATA): The 10/100Base-T Ethernet port (RJ-45) for connection to local network
equipment.
OUTPUT
(DATA & POWER): The 10/100Base-T Ethernet port (RJ-45) port to carry
signal and power to the AN-80i outdoor unit.
The PoE adapter must be installed indoors, located close to a reliable AC or DC power
(based on the type of PoE purchased for this deployment).
AC Power
: The AC model indoor Power-over-Ethernet (PoE) power block is auto-
sensing 110-240 VAC. A grounded AC outlet must be provided within about
one meter of the PoE adapter mounting location. The AC power cable is
supplied with a grounding power plug. Do not defeat this important safety
feature.
DC Power
: The DC model indoor Power-over-Ethernet (PoE) power block is auto-
sensing 18 - 80 VDC. Customer must supply wiring of adequate guage.
Warning to Service Personnel: 48 VDC
Customer equipment including personal computers, routers, etc., must be connected
only to the INPUT (DATA) port on the PoE unit. Only the outdoors Ethernet interface
cable connecting to the AN-80i can be safely connected to the OUTPUT (DATA &
POWER) connector. Connecting customer premises Ethernet equipment directly to the
OUTPUT (DATA & POWER) connector on the Power-over-Ethernet power adapter
may damage customer equipment.
Figure 39: Intro - Indoor Power-over-Ethernet (PoE) Module - AC Model