1.
The AC wall outlet ground for the indoor POE adapter should be connected to the
building grounding system.
2.
Install a surge arrestor in series with the Ethernet cable at the point of entry to the
building. The grounding wire should be connected to the same termination point
used for the tower or mast.
3.
Provide direct grounding connections from the mounting bracket, the antenna, and
the Ethernet cable surge protection to the common building ground bus. Use the
grounding screws provided for terminating the ground wires.
1.5
Deployment in the USA and Canada
1.5.1 FCC & IC Notices
1.
The Model AN-80i and its antenna must be professionally installed.
2.
WARNING -- FCC & IC RF Exposure Warnings
To satisfy FCC and IC RF exposure requirements for RF transmitting devices, the
following distances should be maintained between the antenna of this device and
persons during device operation:
Table 1
:
FCC & IC RF Recommended Safe Separation Distances
Frequency (GHz)
Mode
Separation Distance
3.3 - 3.8
PTP / PMP
130 cm (52 in) or more
4.9 - 5.3
PTP / PMP
255 cm (101 in) or more
5.4
PTP / PMP
40 cm (16 in) or more
5.8
PMP
20 cm (8 in) or more
PTP
310 cm (122 in) or more
To ensure compliance, operation at closer than these distances is not
recommended. The antenna used for this transmitter must not be collocated in
conjunction with any other antenna or transmitter.
3.
High power radars are allocated as primary users (meaning they have priority) of 5.250-5.350
MHz and 5.650-5.850 GHz and these radars could cause interference and/or damage to LE-
LAN devices.
4.
FCC Information to Users @ FCC 15.105:
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications.
Where DFS is required by regional regulations, this function is permanently enabled at the
factory and can not be disabled by the installer or end-user.
5.
FCC Information to Users @ FCC 15.21:
Warning: Changes or modifications not expressly approved by Redline Communications