Figure 24: Weatherproof Ethernet Port - Ethernet Cable Locking Tab
A plastic removal tool is available from Redline to safely and easily disconnect the
Ethernet cable from the AN-80i. Simply align the tool on the Ethernet cable and apply
light pressure to release the locking tab. When the tab has been properly released, the
cable should be able to be removed using only a very light pull (two fingers).
Figure 25: Weatherproof Ethernet Port - Disconnecting the Ethernet Cable
CAUTION: Ethernet Cable Removal
Use of excessive force when removing the Ethernet cable will damage the RJ-45
connector and the AN-80i printed circuit board.
1.
Do not insert any tool more than 1/2 inch into the port opening.
2.
Apply only very light upward pressure on the tool to unclip the plastic tab holding
the RJ-45 connector.
3.
Use only a light pull (two fingers) to remove the Ethernet cable.