3.4.6
Weatherproof LP Connections
It is important to weatherproof both ends of the line protection unit.
1.
Begin to wrap the splicing tape. Start as close to the LP housing as possible. Stretch
and wind the tape back along the connector housing making very sure there are no
gaps in the tape.
Figure 34: Weatherproofing - LP Ethernet Cable Entry - Pt-1
2.
Continue to wrap the tape tightly along the cable.
Figure 35: Weatherproofing LP Ethernet Cable Entry - Pt-2
3.
Work the mastic putty into the area between the connector and the body of the LP.
Continue to work the putty in making a watertight seal. The connection is now well
weatherproofed.
Figure 36: Weatherproofing LP Ethernet Cable Entry - Pt-3
Repeat this procedure for both cable connections to the LP.