WELDING FUMES AND GAS 

 
The fumes, gases and dust produced during welding are hazardous. It is mandatory to ensure adequate 
ventilation and/or extraction to keep fumes and gases away from the work area. An air fed helmet is 
recommended in cases of insufficient air supply in the workplace. 
Check that the air intake is in compliance with safety standards. 
 

Care must be taken when welding in small areas and the operator will need supervision from a safe distance. Welding certain 
pieces of metal containing lead, cadmium, zinc, mercury or beryllium can be extremely toxic. The user will also need to 
degrease the workpiece before welding.  
Gas cylinders must be stored in an open or ventilated area. The cylinders must be in a vertical position secured to a support or 
trolley.  
Do not weld in areas where grease or paint is stored. 
 

FIRE AND EXPLOSIONS RISKS 

 

Protect the entire welding area. Compressed gas containers and other inflammable material must be moved to a 
minimum safe distance of 11 meters. A fire extinguisher must be readily available. 
 
Be careful of spatter and sparks, even through cracks. It can be the source of a fire or an explosion. 
Keep people, flammable objects and containers under pressure at a safe distance. 

Welding of sealed containers or closed pipes should not be undertaken, and if opened, the operator must remove any 
inflammable or explosive materials (oil, petrol, gas...). 
Grinding operations should not be directed towards the device itself, the power supply or any flammable materials. 
 

GAS BOTTLE 

 

Gas leaking from the cylinder can lead to suffocation if present in high concentrations around the work area. 
 
Transport must be done safely: Cylinders closed and product off. Always keep cylinders in an upright position 
securely chained to a fixed support or trolley. 
Close the bottle after any welding operation. Be wary of temperature changes or exposure to sunlight. 
Cylinders should be located away from areas where they may be struck or subjected to physical damage. 
Always keep gas bottles at a safe distance from arc welding or cutting operations, and any source of heat, 
sparks or flames. 
Be careful when opening the valve on the gas bottle, it is necessary to remove the tip of the valve and make 
sure the gas meets your welding requirements. 

 

ELECTRIC SAFETY 

 

The machine must be connected to an earthed electrical supply. Use the recommended fuse size. 
An electrical discharge can directly or indirectly cause serious or deadly accidents. 
 
Do not touch any live part of the machine (inside or outside) when it is plugged in (Torches, earth cable, 
cables, electrodes) because they are connected to the welding circuit. 

Before opening the device, it is imperative to disconnect it from the mains and wait 2 minutes, so that all the capacitors are 
discharged. 
Do not touch the torch or electrode holder and earth clamp at the same time. 
Damaged cables and torches must be changed by a qualified and skilled professional. Make sure that the cable cross section is 
adequate with the usage (extensions and welding cables). Always wear dry clothes in good condition, in order to be insulated 
from the electrical circuit. Wear insulating shoes, regardless of the environment in which you work in. 
 

EMC CLASSIFICATION 

 

These Class A devices are not intended to be used on a residential site where the electric current is supplied by 
the public network, with a low voltage power supply. There may be potential difficulties in ensuring 
electromagnetic compatibility on these sites, because of the interferences, as well as radio frequencies. 
 

 
 
 
 
 
 

Содержание 013643

Страница 1: ...WELDING MACHINE MMAX7 1 EN INSTRUCTION MANUAL 4 DE BEDIENUNGSANLEITUNG 9 RU 15...

Страница 2: ...18 x 14 cm Weight Gewicht 5 kg The duty cycles are measured according to standard EN60974 1 at 40 C and on a 10 min cycle While under intensive use to duty cycle the thermal protection can turn on in...

Страница 3: ...TZTEILE CIRCUIT DIAGRAM SCHALTPLAN 1 Connectors Schwei buchsen 51469 2 Potentiometer knob Drehregler des Potentiometers 73099 3 Electronic card PCB Elektronikplatine 97176C 4 Fan Ventilator 51021 5 Po...

Страница 4: ...efore using this device To protect oneself as well as the other ensure the following safety precautions are taken In order to protect you from burns and radiations wear clothing without cuffs These cl...

Страница 5: ...ers closed and product off Always keep cylinders in an upright position securely chained to a fixed support or trolley Close the bottle after any welding operation Be wary of temperature changes or ex...

Страница 6: ...his device Exposure to electromagnetic fields while welding may have other health effects which are not yet known RECOMMENDATIONS TO ASSESS THE WELDING AREA AND WELDING INSTALLATION Overview The user...

Страница 7: ...ls or metallic building structures the earthing of the part can in some cases but not systematically reduce emissions It is preferable to avoid the earthing of parts that could increase the risk of in...

Страница 8: ...work with generators as long as the auxiliary power matches these requirements The voltage must be AC always set as specified and the peak voltage below 400V The frequency must be between 50 and 60 Hz...

Страница 9: ...ahlung elektromagnetische St rungen Personen mit Herzschnittmacher oder H rger t sollten sich vor Arbeiten in der N he der Maschinen von einem Arzt beraten lassen elektrische Schl ge Schwei l rm und r...

Страница 10: ...cherheitsabstand zu Personen entflammbaren Gegenst nden und Druckbeh ltern Schwei en Sie keine Beh lter die brennbare Materialien enthalten auch keine Reste davon Gefahr entflammbarer Gase Bei ge ffne...

Страница 11: ...f r Passanten oder individuelle Risikobewertung f r Schwei er Alle Schwei er sollten gem dem folgenden Verfahren die Exposition zu elektromagnetischen Feldern aus Lichtbogenschwei ger ten minimieren E...

Страница 12: ...ner Weise ge ndert werden mit Ausnahme der in den Anweisungen des Ger teherstellers erw hnten nderungen und Einstellungen F r die Einstellung und Wartung der Lichtbogenz nd und stabilisierungseinricht...

Страница 13: ...eignet zum Verschwei en aller g ngigen Rutil Edelstahl Guss und basischen Elektroden und verf gen ber einen speziellen Schutz f r das Schwei en an Stromerzeugern Generator 230V 15 GER TEBESCHREIBUNG D...

Страница 14: ...ie bis das Ger t wieder abgek hlt ist Die Netzanzeige leuchtet das Ger t liefert jedoch keinen Strom Masseklemme oder Elektrodenhalter Kabel sind nicht korrekt mit dem Ger t verbunden berpr fen Sie di...

Страница 15: ...MMAX7 15 RU 10 40 C 14 104 F 20 55 C 4 131 F 50 40 C 104 F 90 20 C 68 F 2000 6500 10...

Страница 16: ...MMAX7 16 RU 11 2...

Страница 17: ...MMAX7 17 RU A CEI 61000 3 12 EN 61000 3 11 Zmax X X O MMAX7 Zmax 0 25 O EMF EMF C A...

Страница 18: ...MMAX7 18 RU B C D E F G H c 10 CISPR 11 2009 B C D E F 10...

Страница 19: ...MMAX7 19 RU IP21 12 5 MMAX7 MMA DC 230 15 16A CEE7 7 230 50 60 I1eff 32A MMAX7 MMAX7 400 50 60...

Страница 20: ...MMAX7 20 RU 3 Hot Start Arc Force Anti Sticking TIG DC TIG...

Страница 21: ...entspricht europ ischen Richtlinien Die Konformit tserkl rung finden Sie auf unsere Webseite EN60974 1 EN60974 10 Class A The device complies with EN60974 1 EN60974 10 Class A standard relative to wel...

Страница 22: ...ly Produkt muss getrennt ensorgt werden Werfen Sie das Ger t nicht in den Haus m ll The product s manufacturer contributes to the recycling of its packaging by contributing to a global recycling syste...

Страница 23: ...MMAX7 23 12 5...

Страница 24: ...MMAX7 24 _______________ ________________ ________________ ______________________ _____________________ ____________________________________________...

Страница 25: ...______________________ ___________________ ____ _____________20 __ ____________________________________ 1 _____ _________________20 ___ _____________________________________ __________________________...

Отзывы: