O
A
O
V
V
B
C
C
G
F
E
D
11-CLEANING AND MAINTENANCE
62
PERIODIC CLEANING PERFORMED BY A QUALIFIED TECHNICIAN
CLEANING THE EXCHANGER AND PIPE UNIT
CLEANING THE UPPER COMPARTMENT
When the boiler is cold lift the ceramic top; remove screws “
O
” to the right and left and remove cover “
A
”. Then remove the the fixing screws
from drivers “
V
” and remove boiler cover “
B
”.
At this point, remove the four turbulators “
C
” and using a rigid rod or a bottle brush, clean the internal pipe unit and the turbulators,
removing all of the accumulated ash.
Check the cover gasket and replace it if necessary.
ATTENTION: It is advisable to carry out the cleaning of the upper exchanger at the end of the season and possibly by
an authorised technician in order to also replace the gasket located below plug “B”.
CLEANING THE LOWER COMPARTMENT
Remove ash pan “
D
” and empty it.
Lower lever “
E
” and extract drawer “
F
”. Remove the ash from the drawer and if needed use a vacuum cleaner to remove any other ash or
soot that has built-up under the drawer. Remove brazier “
G
” and clean it every 2/3 days. Check the seal of the ceramic fibre gasket on the
plug and replace it if necessary.
Check the seal of the door gasket and replace it if necessary.
At the end of the season one must clean the compartment under the brazier and the inside of the heat exchanger.
This general cleaning should be carried out at the end of the season in order to facilitate the general removal of all combustion residues,
without waiting too long, because with time and humidity these residues can become compacted.
Содержание LOTUS HYDRO
Страница 1: ...INSTALLATION AND USER GUIDE EN PELLET STOVE LOTUS HYDRO MODEL Translation of original instructions...
Страница 22: ...3 DRAWINGS ANDTECHNICAL SPECIFICATIONS 20 DRAWINGS AND CHARACTERISTICS LOTUS HYDRO DIMENSIONS in cm...
Страница 52: ...LOTUS HYDRO RED 8 MENU ITEMS AND OPERATION 50 ONLY FOR UK...
Страница 54: ...LOTUS HYDRO RED 8 MENU ITEMS AND OPERATION 52 ONLY FOR UK...
Страница 71: ......