background image

INSTALLATION AND USER GUIDE

EN

PELLET STOVE

LOTUS

HYDRO MODEL

Translation of original instructions

Содержание LOTUS HYDRO

Страница 1: ...INSTALLATION AND USER GUIDE EN PELLET STOVE LOTUS HYDRO MODEL Translation of original instructions...

Страница 2: ...AND TECHNICAL SPECIFICATIONS 20 4 INSTALLATION AND ASSEMBLY 22 5 PLUMBING CONNECTION 26 6 ELECTRICAL CONNECTIONS 31 7 INITIAL START UP 32 8 MENU ITEMS AND OPERATION 36 9 SAFETY DEVICES AND ALARMS 55 1...

Страница 3: ...system installed By system one means Stove Chimney Air inlet REVISIONSTOTHE PUBLICATION The content of this manual is strictly technical and the property of RED No part of this manual may be translate...

Страница 4: ...lied with to ensure the product and any electronic appliances connected to it are used correctly and accidents are prevented This appliance can be used by children aged from 8 years and above and pers...

Страница 5: ...mulated unburned pellets in the burner after each failed start up must beremovedbeforelightingagain Checkthattheburneriscleanandpositioned properly before lighting again Shut the stove down in the eve...

Страница 6: ...contact the competent authorities The product and the cladding must be stored in a dry place and must not be exposed to weathering It is recommended not to remove the feet that support the product in...

Страница 7: ...age for a period of 2 two years from the date of purchase attested by a document to serve as proof of purchase invoice and or receipt that shows the name of the vendor and the date on which the purcha...

Страница 8: ...erformedonanannualbasisbyanauthorisedtechnicianorqualifiedpersonnelwillresultinthe loss of the warranty Also excluded from this guarantee are parts subject to normal wear such as gaskets glass claddin...

Страница 9: ...authorisation Allpartsmustbereplacedwithoriginalspareparts WARNINGS FORTHE CORRECT DISPOSAL OFTHE PRODUCT The owner is the sole party responsible for demolishing and disposing of the product This must...

Страница 10: ...the choice of smoke duct flue UNI 10847 2000 Smoke extractor systems for liquid and solid fuelled generators Maintenance and control Guidelines and procedures UNI 8065 water treatment in civil plants...

Страница 11: ...soning whereas that of pellets is 4 9 kW kg To ensure good combustion the pellets must be stored in a dry place and protected from dirt Pellets are usually supplied in 15 kg bags therefore storing the...

Страница 12: ...rniture andwithgoodaircirculation to allow effective ventilation for the appliance The product should be located in an area that allows sufficient space for normal use and maintenance operations The v...

Страница 13: ...re with a minimum clearance to allow effective aeration of the appliance and a good distribution of heat in the room Observe the distances from flammable or heat sensitive objects sofas furniture wood...

Страница 14: ...insulate the pipe of the product that passes through it using adequate insulating materials 1 3 5 cm thick with minimum thermal conductivity 0 07W m K The same minimum distance must be applied if the...

Страница 15: ...tion of a solid fuel burning heating appliance with natural draught as modern heating appliances have high efficiency with cooler flue gasses and consequently less draught it is therefore essential th...

Страница 16: ...eparatedfromcombustibleorflammablematerialswithanairgaporinsulatingmaterials checkthedistance specified by the manufacturer of the fireplace according to EN1443 The chimney opening must be in the same...

Страница 17: ...configurations must be correctly dimensioned in accordance with the general method of calculation of UNI EN13384 1 or other proven efficiency methods Below is a list of some flues available on the ma...

Страница 18: ...rucial element for the heating appliance to work properly we recommend a wind proof chimney A see Figure 7 The area of the opening for smoke extraction must be at least double the cross section of the...

Страница 19: ...n hood other stoves etc which could cause cause depression in the room One must verify that with all the equipment on the pressure drop between the room and the outside does not exceed a value of 4 Pa...

Страница 20: ...T200 class P1 The use of flexible metal tubes in fibre cement or aluminium is prohibited For direction changes we always recommend the use of aT jointwith an inspection cap allowing easy access for cl...

Страница 21: ...data tags on the flue in particular the minimum safety distances from combustible materials The previous rules also apply for holes made in walls 2 Oldflue minimumpipe 100mmwiththeinclusionof an exter...

Страница 22: ...3 DRAWINGS ANDTECHNICAL SPECIFICATIONS 20 DRAWINGS AND CHARACTERISTICS LOTUS HYDRO DIMENSIONS in cm...

Страница 23: ...2 Pa Mass of smoke 17 1 g sec Hopper capacity 106 litri Type of pellet fuel Pellet diameter 6 8 mm and size 3 40 mm Pellet hourly consumption Min 1 2 kg h Max 5 2 kg h Autonomy At min 60 h At max 14 h...

Страница 24: ...nd its glass are protected from knocks that might compromise their integrity Always handle the product with care If possible unpack the stove near the chosen place of installation The materials that m...

Страница 25: ...e product must be connected to an exhaust pipe that goes through the rear wall to enter the chimney make sure not to force it in Adjust the 4 feet J to level the stove so that the smoke exhaust and th...

Страница 26: ...ading lid A Open door B Remove the two front screws C and the two rear screws C Remove lid D At this point take the three ceramic side panels E and insert them as shown in the figure The six ceramic s...

Страница 27: ...n is prohibited ASSEMBLINGTHETOP Thetopdoesnotrequireparticularfasteningasitisonlyrestedonthestructureoftheproductinlinewiththerelativevibrationdampers So once panels E have been fitted and piece D re...

Страница 28: ...QCF recognised biomass qualification Any company using sub contractors MUST ensure they also hold the relevant qualifications ONLY FOR UK 1 OUTLET 5 1 2 G MALE DOMESTICWATER INLET 2 SAFETYVALVE 6 3 4...

Страница 29: ...ined in the boiler to the plate heat exchanger The temperature of the domestic water highly depends on the temperature of the water inside the heating system This can be calculated to a good degree of...

Страница 30: ...alve 6 isalwaysconnectedtoawaterdrainingpipe Thepipemustbeadequatetosupportthewater s hightemperatureandpressure A DOMESTIC WATER OUTLET B DOMESTIC WATER INLET C HEATING RETURN D HEATING DELIVERY E EX...

Страница 31: ...of water circulating in the expansion tank The content of water in the recycling system must be kept constant Practical experience demonstrates that the water level must be inspected regularly every...

Страница 32: ...this value act on the system filling tap The operation must be carried outwhenthesystemiscold Thesystempressuregaugeenablestomonitorthepressureinthecircuit To fill the system the boiler is fitted with...

Страница 33: ...ic cables do not leave the appliance exposed to weathering rain sun etc do not allow the appliance to be used by children or inexperienced persons 230V electrical power supply connection Installation...

Страница 34: ...llation may not be correct REMOVETHEPELLETSFROMTHEBRAZIERANDCONTACTANAUTHORISEDTECHNICIAN Avoid touching the stove during the initial start up as the paint in this stage hardens by touching the paint...

Страница 35: ...ENTION If during operation or initial ignition you encounter smoke spillage in to the room from the appliance orthefluethenpleaseswitchofftheappliance ventilatetheroomandcontacttheinstallation service...

Страница 36: ...uel other then pellets in compliance with above mentioned specifications is to be inserted into thehopper DUCT FOR ADDITIONALTANK optional One can purchase a duct to be fixed via four screws to the re...

Страница 37: ...failed ignitions What to do in the event of alarms in particular those generated when the appliance runs out of fuel How to maintain the appliance correctly and the importance of carrying out these ta...

Страница 38: ...ctions 7 Display MAIN MENU It is accessed by pressing key 3 menu The items that are accessed are Date andTime Timer Sleep only with the stove on Settings Info Date and time setting To set the date and...

Страница 39: ...1 press the Menu key press and select ON confirm with the Menu key Atthispointitwillpropose00 00asstartingtime withkey adjustthestartingtimeandpressthe menu keytoconfirm The next step proposes a shutd...

Страница 40: ...and the stove will switch on it will switch off at the time set on the active timer SLEEP FUNCTION main menu The sleep function is activated only when the stove is switched on and allows to quickly se...

Страница 41: ...ain system configurations a Language To select the language act as follows Press the menu button Scroll to Settings using the arrows Press menu to confirm Scroll to language using the arrows Press men...

Страница 42: ...ive chapter EXTERNALTHERMOSTAT not included with the boiler to be provided by the user The temperature of the stove can also be controlled by an external room thermostat It is located in a central pos...

Страница 43: ...o exit AUTO ECO MODE see section 8f and 8g To activate the Auto Eco mode and adjust the time refer to section 8 f and 8 g respectively The possibility to adjust the ECO shutdown t comes from the need...

Страница 44: ...and esc to exit i Auxiliary boiler Onemustinstallanadditionalmodule optional toenablestart upofanauxiliaryboilerintheevemtthestoveisswitchedofforinalarm conditions By default this function is deactiva...

Страница 45: ...menu button Scroll to Settings using the arrows Press menu to confirm Scroll to Maximum power using the arrows Press menu to confirm Change the power from 01 to 05 with the keys Press menu to confirm...

Страница 46: ...active At any time the technician can interrupt this stage by quickly pressing the on off key To activate the Chimney sweep function act as follows Press the menu button Scroll to Settings using the...

Страница 47: ...o change the function act as follows Press the menu button Scroll to Settings using the arrows Press menu to confirm Scroll to Season using the arrows Press menu to confirm Select Summer or Winter wit...

Страница 48: ...instantaneous hot domestic water production with plate heat exchanger FACTORY CONFIGURATION 2 2 Room temperature management via the stove probe or by enabling the external room thermostat instantaneou...

Страница 49: ...5 1 3 2 7 11 8 9 6 4 10 8 MENU ITEMS AND OPERATION 47 Technical Dept All rights reserved Reproduction is prohibited CONFIGURATION 2 1 FACTORY SETTING CONFIGURATION 2 2 DISCONNECT INTERNALTHREE WAYVALV...

Страница 50: ...5 5 3 2 9 7 6 8 11 1 12 4 5 5 4 4 2 1 3 14 15 13 11 17 6 8 MENU ITEMS AND OPERATION 48 CONFIGURATION 3 DISCONNECT INTERNALTHREE WAYVALVE AND FLOW SWITCH CONFIGURATION 4...

Страница 51: ...US 2 HEATING DELIVERY 3 HEATING RETURN 4 ZONEVALVES 5 HEATING BODIES 6 DOMESTIC HOTWATER 7 COLD DOMESTICWATER 8 DOMESTICWATER BOILER 9 DIVERTERVALVE 10 BOILERTHERMOSTAT 11 THERMOSTATIC MIXINGVALVE 12...

Страница 52: ...LOTUS HYDRO RED 8 MENU ITEMS AND OPERATION 50 ONLY FOR UK...

Страница 53: ...LOTUS HYDRO RED 8 MENU ITEMS AND OPERATION 51 Technical Dept All rights reserved Reproduction is prohibited ONLY FOR UK...

Страница 54: ...LOTUS HYDRO RED 8 MENU ITEMS AND OPERATION 52 ONLY FOR UK...

Страница 55: ...LOTUS HYDRO RED 8 MENU ITEMS AND OPERATION 53 Technical Dept All rights reserved Reproduction is prohibited ONLY FOR UK...

Страница 56: ...with a flashing flame When the flame stops flashing the stove has reached the power output operating mode The room temperature set by default is 20 C if one wishes to change it act as instructed in th...

Страница 57: ...shutdown ELECTRICAL SAFETY The product is protected against sudden current surges by a main fuse in the power supply panel on the rear part of the product Other fuses that protect the electronic board...

Страница 58: ...ll the necessary measures and or precautions must be adopted when performing maintenance cleaning and repairs Donottamperwiththesafetydevices Donotremovethesafetydevices Connecttheproducttoanefficient...

Страница 59: ...ets loading SETTINGS menu Pellets recipe A05 Pressure switches alarm Smoke pressure switch intervention or water pressure insufficient Verify chimney obstruction door opening or hydraulic system press...

Страница 60: ...power cut BLACKOUT the stove behaves as follows Blackout below 10 it returns to its operation in progress Intheeventofapowercutthatlastsover10 withthestoveonorinthestart upstage whenthestoveispowereda...

Страница 61: ...fundamental to guarantee that the product is installed in compliance with standards in force Furthermore it is of the utmost importance to respect the following simple rules Every time the brazier is...

Страница 62: ...each start up Only if ash is completely cold may a vacuum cleaner be used to remove it In this case use a suitable vacuum cleaner to remove small sized particles REMEMBER THAT ONLY A CORRECTLY POSITIO...

Страница 63: ...ximum power to expel the soot that is dislodged when the exchanger is cleaned Clean the pipe unit Using the cold handle supplied the cold handle hangs inside the stove door fig 2 shake vigorously the...

Страница 64: ...n and possibly by anauthorisedtechnicianinordertoalsoreplacethegasketlocatedbelowplug B CLEANINGTHE LOWER COMPARTMENT Remove ash pan D and empty it Lower lever E and extract drawer F Remove the ash fr...

Страница 65: ...retailer or contact an authorized service centre to carry out this task ATTENTION The frequency with which the smoke exhaust must be cleaned depends on the use of the boiler and the type of installati...

Страница 66: ...r Smoke expulsion fan Smoke probe Start up spark plug Automatic resettable pellet water thermostat Room water probe Motherboard Panel motherboard protection fuses Cabling PARTS INTERVAL 2 3 DAYS EVERY...

Страница 67: ...or Faulty electronic board Replacethecircuitboard The fire goes out or the boiler stops automatically The pellet hopper is empty Fill the hopper with pellets The pellets are not fed See the previous a...

Страница 68: ...r and smoke duct Check that the air inlet is not obstructed Damp or unsuitable pellets Change the type of pellets Faulty smoke evacuation motor Checkthemotorandreplaceit ifnecessary The smoke evacuati...

Страница 69: ...ty Check and clean the boiler Insufficient boiler power Check that the boiler is properly sized for the requirements of the system Poor pellet quality Use quality pellets Condensation in boiler Incorr...

Страница 70: ...NAL BLOCK 12 FEED SCREW 13 SMOKE PROBE 14 EXTERNALTHERMOSTAT CONNECTION TERMINAL BLOCK 15 INTERNAL ROOM PROBE 16 PUFFER BOILER PROBE CONNECTION TERMINAL BLOCK 17 BOILERWATERTEMPERATURE PROBE 18 SMOKE...

Страница 71: ......

Страница 72: ...REV 3 8901228900 12 01 2015 Via La Croce n 8 33074Vigonovo di Fontanafredda PN ITALY Telefono 0434 599599 r a Fax 0434 599598 Internet www mcz it e mail info red mcz it...