s
F
E
28
19-CLEANING AND MAINTENANCE
CLEANING THE PIPE UNITS
For better performance of the boiler, the pipes inside the combustion chamber should be cleaned once a month.
Open the firebox door and use the brush provided to clean the 5 pipes positioned at the top inside the combustion chamber. Brush the
pipes several times so that the ash deposited inside them falls to the bottom around the brazier.
Use a vacuum cleaner to remove all fallen material.
PERIODIC CLEANING PERFORMED BY A QUALIFIED TECHNICIAN
CLEANING THE SMOKE EXTRACTOR COMPARTMENT
In the area behind ash pan “
D
”, there is the smoke cap “
E
”, which must be removed to clean the smoke extractor. Therefore:
• loosen the screws “
s
”
• remove cap “
E
”
Now, using the nozzle of a vacuum cleaner, remove any ash and soot that may have built up in the lower exchanger indicated by the arrow.
Before putting the cap “
E
” back, changing gasket “
F
” is recommended
Before removing ash using a vacuum cleaner, it is recommended to clean the internal walls of the stove using the supplied scraper.