TIME CODE
Selects the TIME CODE source to be used. Options are EXTERNAL TC and INTERNAL USER-
PROVIDED TC.
EXTERNAL TC
When selected, the camera reads the external SMPTE timecode signal and synchronizes its internal
timecode counter to that value at the beginning of each recording.
INT USER-PROVIDED TC
Available options are USE RTC TIME and SET MANUALLY. The three (3) numerical boxes below allow
you to set hours, minutes and seconds (in that order).
Use RTC Time
When selected the camera uses the camera’s Real Time Clock as the timecode counter source.
Set Manually
When selected allows the user to define a custom value as the timecode counter seed.