68
x
V
13 - MAINTENANCE AND CLEANING
PERIODIC CLEANING PERFORMED BY A QUALIFIED TECHNICIAN
CLEANING THE EXCHANGER AND PIPE UNIT
CLEANING THE UPPER COMPARTMENT
With the boiler cool and after removing the covers (see paragraph on panel removal); loosen the 4 M6 screws "
x
" on the right and left
and lift the cover "
V
" (fig.3).
The three pipes have now been extracted (fig.4). Using a rod or a brush for cleaning bottles, clean inside the pipe unit and the pipes,
removing any ash deposits (fig.5).
Check the cover seal and replace it if necessary.
ATTENTION: the exchanger must be cleaned at the end of the season by an authorised technician so that any worn
seals may be replaced.
Figure 3
Содержание COMPACT SLIM 15
Страница 1: ...INSTALLATION GUIDE GB Translation of original instructions PELLET BOILER COMPACT SLIM 15...
Страница 30: ...28 B C A 6 PANEL REMOVAL Upper top Lift top A remove and secure tops B and C Tops B and C are only supported...
Страница 38: ...36 n V r 7 HYDRAULIC CONNECTION FIGURE3 FIGURE4...
Страница 71: ...69 13 MAINTENANCE AND CLEANING Technical Dept All rights reserved Reproduction is prohibited Figure5 Figure4...