13 - MAINTENANCE AND CLEANING
Technical Dept. - All rights reserved - Reproduction is prohibited
CLEAN THE EXCHANGER AND THE COMPARTMENT BENEATH THE BRAZIER EVERY 2/3 DAYS
Cleaning the exchanger and the compartment beneath the brazier is a simple operation but very important if the boiler is to maintain
optimal performance.
We therefore recommend cleaning the internal exchanger every 2-3 days, performing these simple operations in sequence:
•
Activate the "CLEANING" function
- with the boiler off press - menu, select "Settings", with the arrows <> select "Cleaning",
confirm with the "Menu" key, activate the cleaning "ON" with the + - keys. This procedure starts the smoke extractor on the
maximum setting to expel the soot that becomes dislodged when the exchanger is cleaned.
•
Clean the pipe unit
- Using the hook provided, shake the rods located beneath the cover "
B
" firmly 5-6 times. This should remove
the soot that has deposited on the smoke ducts of the exchanger during normal use of the boiler (
fig. 1
).
•
Deactivate the "CLEANING" function
- this function is deactivated automatically after two minutes. If you need to stop the
function sooner, press the "Esc" key.
•
Clean the smoke conveyor compartment (fig.2) -
The boiler is equipped with a removable ash tray "
H
" which collects any
accumulations of soot and ash.
• When done cleaning, close the cover and ash tray.
If the cleaning is not done every 2-3 days, the boiler could go into alarm caused by ash clogging after several hours
of operation.
Figure 1
Figure 2
Содержание COMPACT SLIM 15
Страница 1: ...INSTALLATION GUIDE GB Translation of original instructions PELLET BOILER COMPACT SLIM 15...
Страница 30: ...28 B C A 6 PANEL REMOVAL Upper top Lift top A remove and secure tops B and C Tops B and C are only supported...
Страница 38: ...36 n V r 7 HYDRAULIC CONNECTION FIGURE3 FIGURE4...
Страница 71: ...69 13 MAINTENANCE AND CLEANING Technical Dept All rights reserved Reproduction is prohibited Figure5 Figure4...