RAM-6021 Wired Router
97
Automation Tab
•
Reg/Index
0
‐
1,
3,
5
and
8
‐
10
will
be
set
to
Default
DeadBand
and
Class
Assignments.
•
Reg/Index
2,
4,
and
6
‐
7
will
be
set
to
Exception
DeadBand
and
Class
Assignments.
Note:
The
order
of
table
entry
ranges
MUST
be
entered
from
lowest
Reg/Index
to
highest
Reg/Index,
otherwise
the
Web
UI
will
Alert
the
end
user
for
incorrect
range
entries.
The
Starting
Reg/Index
and
Ending
Reg/Index
of
Exception
table
entries
for
a
single
Reg/Index
such
as
Reg/Index
2
and
4
in
aove
example
has
to
be
the
same
address.
The
Maxi
‐
mum
suggested
entries
for
Exception
table
are
10
‐
15
entries.
•
Click
the
Add
button
to
add
Exceptions
to
the
table.
Starting
Reg/Index
(Required):
Enter
the
Starting
Register
for
exception
class
requirements.
The
valid
ranges
are
(0
‐
8201)
and
must
be
less
than
or
equal
to
Ending
Register.
Ending
Reg/Index
(Required):
Enter
the
Ending
Register
for
exception
class
assignments.
The
valid
ranges
are
(0
‐
8201)
and
must
be
greater
than
or
equal
to
Starting
Register.
Enter
DeadBand
Value:
Values
outside
this
deadband
generate
events.
Note:
The
deadband
parameter
sets
how
event
data
is
generated
by
your
module
as
aDNP
slave
device.
For
example:
The
Analog
Input
deadband
being
set
to
a
value
of
1000
will
report
all
of
the
points
as
being
class
3
data
(as
set
by
the
"Analog
Input
class"
parameter
being
set
to
3)
and
it
will
generate
an
event
every
time
an
analog
input
changes
by
a
value
of
1000
or
more.
This
Analog
Input
deadband
can
be
set
to
any
value
between
0
to
32767
(gener
‐
ate
an
event
when
the
value
changes
by
32767).
Object
31
‐
Frozen
Analog
Input:
This
field
is
activated
on
both
Levels
2
and
2+.
It's
used
to
determine
if
a
DNP
point
will
generate
events.
In
case
a
DNP
point
generates
events
(Object2
Binary
Change
Events)
then
it
should
be
associ
‐
ated
to
a
class
(Class
1,
Class2
or
Class
3),
otherwise
it
should
be
associated
to
None.
By
default
all
DNP
Points
don't
generate
events,
this
feature
should
be
modified
by
the
user.
Object
32
‐
Analog
Change
Event:
This
field
is
activated
on
both
Levels
2
and
2+.
It's
used
to
determine
if
a
DNP
point
will
generate
events.
In
case
a
DNP
point
generates
events
(Object2
Binary
Change
Events)
then
it
should
be
associ
‐
ated
to
a
class
(Class
1,
Class2
or
Class
3),
otherwise
it
should
be
associated
to
None.
By
default
all
DNP
Points
don't
generate
events,
this
feature
should
be
modified
by
the
user.
Object
33
‐
Frozen
Change
Event:
This
field
is
activated
on
both
Levels
2
and
2+.
It's
used
to
determine
if
a
DNP
point
will
generate
events.
In
case
a
DNP
point
generates
events
(Object2
Binary
Change
Events)
then
it
should
be
associ
‐
ated
to
a
class
(Class
1,
Class2
or
Class
3),
otherwise
it
should
be
associated
to
None.
By
default
all
DNP
Points
don't
generate
events,
this
feature
should
be
modified
by
the
user.
•
Click
on
OK
and
then
move
on
to
the
next
tab,
Default