RAM-6021 Wired Router
102
Automation Tab
The
messages
log
shows
that
we
have
"Added
I/O
Range
AI[0:7]
to
Test
I/O"
and
now
we
see
each
register
that
can
be
edited
and
monitored
for
the
Analog
inputs.
You
may
enter
values
here
and
observe
your
IODB
data
from
another
device
/
location
to
see
those
values
get
updated,
or
you
may
initiate
a
change
from
another
device/input
and
observe
the
changes
presented
here
on
your
Test
I/O
interface.
•
Click
on
the
I/O
CTRL
menu
item
and
the
following
window
will
appear:
•
From
the
drop
down
menu
select
Yes
to
enable
this
interface
and
the
following
window
will
appear:
Digital
Input
Address:
Enter
the
address
of
internal
IODB
database
for
Digital
Input
I/O
control.
Valid
values
for
this
field
are
1
through
65535
as
defined
for
specified
I/O
type.
Digital
Input
Counter:
Counts
the
transitions
(number
of
changes
in
digital
state)
on
Digital
Input.
Digital
Output
Address:
Enter
the
address
of
internal
IODB
database
for
Digital
Output
I/O
control.
Valid
values
for
this
field
are
1
through
65535
as
defined
for
specified
I/O
type.