N-Tron® 300 Series Hardware Guide

iii

Preface

Revised 2015-12-04

Preface

Disclaimer

Portions of this document are intended solely as an outline of methodologies to be followed during the 
maintenance and operation of

 

N-Tron

®

 300 series Industrial Ethernet Switch equipment. It is not intended as a 

step-by-step guide or a complete set of all procedures necessary and sufficient to complete all operations.

While every effort has been made to ensure that this document is complete and accurate at the time of release, the 
information that it contains is subject to change. Red Lion Controls is not responsible for any additions to or 
alterations of the original document. Industrial networks vary widely in their configurations, topologies, and traffic 
conditions. This document is intended as a general guide only. It has not been tested for all possible applications, 
and it may not be complete or accurate for some situations.

Users of this document are urged to heed warnings and cautions summarized at the front of the document, such as 
electrical hazard warnings.

Compliance Information

It is recommended that the owner of this equipment determine and ensure conformance with any specific and 
applicable local regulations.

Part 15 of the Federal Communications Commission (FCC) - A Rules: Interference 

Every effort has been made to ensure that this equipment is designed to comply with the limits for a Class A digital 
device, as described in the FCC Rules.

This product complies with Part 15 of the FCC-A Rules.

Operation is subject to the following conditions:

1.

This device may not cause harmful Interference

2.

This device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 
of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a 
residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not 
installed and used in accordance with the instructions, may cause harmful interference to radio communications. 
Operation of this device in a residential area is likely to cause harmful interference in which case the user will be 
required to correct the interference at their own expense.

Industry Canada

This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment 
Regulations. Operation is subject to the following two conditions; (1) this device may not cause harmful 
interference, and (2) this device must accept any interference received, including interference that may cause 
undesired operation.

Cet appareillage numérique de la classe A répond à toutes les exigences de l'interférence canadienne causant des 
règlements d'équipement. L'opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas 
causer l'interférence nocive, et (2) ce dispositif doit accepter n'importe quelle interférence reçue, y compris 
l'interférence qui peut causer l'opération peu désirée.

Содержание N-Tron 302MC

Страница 1: ...N Tron Series 300 Series Media Converter Industrial Ethernet Switches Installation Guide December 2015...

Страница 2: ...ks of their respective owners CONTACT INFORMATION AMERICAS York PA 1 717 767 6511 Mobile AL 1 251 342 2164 Ballston Lake NY 1 518 877 5173 Hours 8am 6pm Eastern Standard Time UTC GMT 5 hours ASIA PACI...

Страница 3: ...Avertissements et mises en garde v General Safety Cautions and Warnings Pr cautions et avertissements de s curit g n rale v Electrical Safety Warnings Avertissements de s curit lectrique vi Environmen...

Страница 4: ...packing 2 5 Inspection 2 5 Installing Mounting 2 5 DIN Rail Mounting 2 7 Connections 2 8 Power Connection 2 8 Ground Connection 2 9 300 Series Grounding Techniques 2 9 RJ45 Connector Crimp Specificati...

Страница 5: ...in the FCC Rules This product complies with Part 15 of the FCC A Rules Operation is subject to the following conditions 1 This device may not cause harmful Interference 2 This device must accept any...

Страница 6: ...X XX 305FXE XX YY 306TX 306FX2 XX 306FXE2 XX YY 308TX Where XX ST or SC and YY 15 40 or 80 Release Notes and Document Updates The hard copy and electronic media versions of this document are revised o...

Страница 7: ...rt peuvent en r sulter Cautions apply to where reduced function or damage to equipment may result Avertissements s appliquent o fonction r duite ou d endommagement de l quipement peut entra ner Genera...

Страница 8: ...c le couvercle retir ceci pourrait cr er une d charge lectrique ou un incendie WARNING Power must be supplied by an isolating source and a 3 3A max rated UL recognized fuse must be installed immediate...

Страница 9: ...re that all devices connected to this product must be UL approved for the area in which it is installed AVERTISSEMENT Classe I Div 2 installations n cessitent que tous les p riph riques connect s ce p...

Страница 10: ...ardware Guide Laser Safety Warning Consignes de s curit relatives au laser CAUTION Only for FXE products CLASS 1 LASER PRODUCT Do not stare into the laser ATTENTION Uniquement pour les produits FXE PR...

Страница 11: ...10 100 Mb and half full duplex communications 305FX and 306FX2 The 305FX and 306FX2 switches are unmanaged and have 4 ports similar to the 304TX plus an additional multimode fiber optic up link port...

Страница 12: ...38 in 85 87mm 0 75 lbs 0 3 kg Electrical Specifications Input Voltage Input Current Input Ripple Input Wire Size 10 30 VDC Regulated 230mA max 24VDC Steady State Less than 100 mV 16 28 AWG Inrush Cur...

Страница 13: ...Regulatory Approvals Safety Suitable for use in Class I Division 2 Groups A B C and D Hazardous Locations or Nonhazardous Locations only EMI EN61000 6 4 EN55011 Class A FCC Title 47 Part 15 Subpart B...

Страница 14: ...Introduction and Specifications Revised 2015 12 04 1 4 N Tron 300 Series Hardware Guide Certifications GOST R Certified...

Страница 15: ...tact your carrier 2 File any damage claims with the carrier Installing Mounting Read the following warning before beginning the installation Lire l avertissement suivant avant de commencer l installat...

Страница 16: ...osure top AVERTISSEMENT D branchez le c ble d alimentation avant de retirer le bo tier sup rieur WARNING Do not operate the unit with the top cover removed as this could create a shock or fire hazard...

Страница 17: ...ead screwdriver into the orange release clip found at the bottom of the unit and apply downward force on the clip until it disengages from the bottom of the unit from the DIN Rail Rotate the bottom of...

Страница 18: ...terminal block power plug is 0 22 Nm 0 162 Pound Foot 5 All LED s will flash ON Momentarily 6 Verify the Power LED stays ON GREEN Note Either V1 or V2 can be connected to power for minimal operation F...

Страница 19: ...or less in length As an alternate users can run a drain wire lug from any of the DIN Rail screws or empty PEM nuts on the enclosure When using an unused PEM nut to connect a ground lug via a machine s...

Страница 20: ...rt to another Switch or Repeater use a standard Cat5 straight through or crossover cable Note For units which have the N View Option you can validate that all ports are working cor rectly by installin...

Страница 21: ...ts and LED indicators and a description of their functions are identified in the following figure and Table 3 Table 3 Port LED Description LNK Link LED for Fiber Optic Ports TX Fiber Optic Transmit Po...

Страница 22: ...between ports OFF Data is inactive between ports Unit LED s Maintenance There are no field serviceable parts to the N Tron 300 series switches Verify Troubleshoot The following procedure provides some...

Страница 23: ...SE OF PERFORMANCE USAGE OF TRADE OR OTHERWISE Customer shall be responsible for determining that a Product is suitable for Customer s use and that such use complies with any applicable local state or...

Страница 24: ...Operation and Maintenance Revised 2015 12 04 3 14 N Tron 300 Series Hardware Guide...

Отзывы: