N-Tron® 300 Series Hardware Guide
1-3
Introduction and Specifications
Revised 2015-12-04
Table 2.
Fiber Length
2km*
15km**
40km**
80km**
TX Power Minimum
-19dBm
-15dBm
-5dBm
-5dBm
RX Sensitivity Maximum
-31dBm
-31dBm
-34dBm
-34dBm
Wavelength
1310nm
1310nm
1310nm
1550nm
[Fiber Transceiver Characteristics
* = Multimode **= Singlemode
Regulatory Approvals
Safety
Suitable for use in Class I, Division 2, Groups A, B, C and D Hazardous Locations, or Nonhazardous Locations
only.
EMI
•
EN61000-6-4, EN55011 - Class A
•
FCC Title 47, Part 15, Subpart B - Class A
EMS
•
EN61000-6-2
•
EN61000-4-2 (ESD)
•
EN61000-4-3 (RS)
•
EN61000-4-4 (EFT)
•
EN61000-4-5 (Surge)
•
EN61000-4-6 (Conducted Disturbances)
Conducted Low Frequency:
IEC60533
Shock:
IEEE 1613 (250 mm)
Vibration
•
IEEE 1613 (V.S.4 150mm/s)
•
IEC60068-2-6 (Test Fc)
Cold:
IEC60068-2-1
Dry Heat:
IEC60068-2-2
Damp Heat:
IEC60068-2-30 (Test Db)