2-INSTALLATION
MAINTENANCE
The flue must be kept clean, since the deposit of soot or unburnt oils reduces the cross-section reducing the draught and thus compromising
the efficient operation of the stove and, if large build-ups accumulate, can catch fire. The flue and chimneypot must be cleaned and
checked by a qualified chimney sweep at least once a year. Once the inspection/maintenance has been performed, request a written
report that the system is safe.
Failure to perform cleaning jeopardises the system’s safety.
CHIMNEYPOT
The chimneypot is a crucial element for the heating appliance to work properly: we recommend a wind proof chimneypot (A), see Figure 7.
The area of the opening for smoke extraction must be at least double the cross-section of the flue/lined system, and arranged so that
smoke outlet is ensured even in strong
wind. The chimneypot must prevent
rain, snow or animals from entering
the chimney. The height of outflow
into the atmosphere must be beyond
the reflux area due to the shape of the
roof or any obstacles near the outlet
(see Figures 2-3-4-5-6).
CHIMNEY COMPONENTS
KEY:
(1) CHIMNEYPOT
(2) REFLUX CHANNEL
(3) SMOKE DUCT
(4) THERMAL INSULATION
(5) OUTSIDE WALL
(6) CHIMNEY FITTING
(7) SMOKE DUCT
(8) HEAT GENERATOR
(9) INSPECTION ACCESS PANEL
FIGURE 7