37
37
7-HYDRAULIC CONNECTION
Technical Dept. - All rights reserved - Reproduction prohibited
ANTI-CONDENSATION VALVE (INCLUDED IN THE HYDRAULIC KIT CODE 40A18013 - 40A18014)
The anti-condensation valve is used in solid fuel boilers to prevent the return of cold water into the boiler or stove, resulting in the
formation of condensation.
The prolonged formation of condensation causes permanent damage to the heat exchanger.
A higher return temperature reduces the formation of condensation of the fumes and extends the life of the boiler.
Valves available on the market offer various calibrations. RED recommends using the model (see accessories list) at 55°C. The thermostatic
sensor immersed directly in the fluid “feels” the temperature and diverts the route according to the required value (55°C).
A N T I - CONDENSATION VALVE INSTALLED ON THE
HYDRAULIC KIT