TEST mode – without alarm function
This function allows the FlipFlow operating modes to be tested without triggering an alarm (no alarm
signal transmitted to the BMS). This function can be activated by turning the rotary button on the con-
trol panel. This function can be used in any operating mode of the FlipFlow. The FlipFlow then oper-
ates normally but without an alarm function. The BMS immediately informed that maintenance is in
progress in this particular tunnel. An acoustical tone sounds at regular intervals as a reminder.
Status of the FlipFlow:
– Depending on the mode selected.
It is permitted to use the service display
NOTICE
Configurable with the service display:
a) Activate/deactivate surveillance of the service display.
b) Select operating mode parameters.
4.2.10
Authorized access airside
When this function is activated, an authorized person is entitled to pass through the FlipFlow in the
opposite direction. This function can be activated with a button or switch provided and installed by the
customer or via the BMS (Building Management System).
Status of the FlipFlow
– Illumination is on
– LED-Strip are red
– Entrance door pictogram is red
Exit door pictogram is green, if access is allowed
Cycle:
If the tunnel is empty and locked, then the middle and exit door will open in this function and after a
delay time or person detection in tunnel 1, the middle and exit door will close again. If there is still a
person inside the tunnel 1, then the entrance door will open to allow the person to leave the tunnel
and then the entrance door will close again. If the tunnel is empty then the FlipFlow will return to the
previously set operating mode.
If there is still a person in the tunnel or a new person has entered the tunnel, the middle and exit door
will open and the person must leave the system in the exit direction.