4
Operation
20 / 38
BAL_FF_TWIN_EN_2V3_REC_121-006454269
NOTICE
Configurable with the service display:
a) Activation / deactivation of the sensors and movement detection.
IMPORTANT
In this mode, the security level is compromised!
If detection in the tunnel is deactivated, it is possible to pass through in both directions without trigger-
ing an alarm.
If detection is activated, it is only possible to pass in the authorized direction without triggering an
alarm.
4.2.4
FLOW operating mode
FLOW mode offers a wide variety of passage possibilities as there are no restrictions for the doors to
open simultaneously, although maintaining a certain level of security thanks to a very low response
time of the anti-pass-back system (TOF-Sensor).
Initial state:
– Illumination is on.
– Entrance door is closed .
– Exit door is closed.
– LED-Strips are green.
– Entrance pictogram is green.
If secured, it is not permitted to use the service display .
Cycle:
– A passenger arrives in front of the entrance radar,
the door opens.