4
Operation
28 / 38
BAL_FF_TWIN_EN_2V3_REC_121-006454269
4.2.11
Emergency opening
When this function is activated, the FlipFlow doors open
regardless of the status of the safety sensors. This mode
is activated in case of fire or emergency by a remote
switch in the building management system. This switch
is provided by the customer and will interrupt the con-
nection between pin 3 and pin 4 on PM11 on the circuit
board of each tunnel.
4.2.12
Emergency closing
When this function is activated, the FlipFlow entry door
will close regardless of the status of the safety sensors.
This mode is activated by a remote switch in the building
management system. This switch is provided by the cus-
tomer and will interrupt the connection between pin 1
and pin 2 on PM11 on the circuit board of the first tunnel.
4.2.13
POWERSAVE function
If the FlipFlow is not used for a certain time, the lights turn off and switch back on automatically for the
next cycle.
NOTICE
Configurable with the service display:
a) Activation / deactivation of functions.
b) Setting the idle time delay.
4.2.14
Power failure
In case of power failure, the backup battery (option) is
activated.
By default, the entrance door is closed and locked. The
exit door is opened.
As soon as the power supply is restored, the last operat-
ing mode set is continued.