HandPunch 50E Manual
Page 33
Calibrate
The Calibrate command displays the HandPunch’s exposure values,
allowing you to verify these values are within normal operating
parameters. The standard operating parameters are shown in Table 5.
Status
Display
The status display command allow you to enable or disable the
displaying of the following information.
•
the status values of HandPunch inputs and outputs
•
the hand read score of the last user to verify on the system
When the status display is enabled, Figure 8-1 identifies each status
display field value.
Figure 8-1 Status Display Chart
Table 5: Normal Operating Parameters
Parameter
Normal Range
Row “r”
0 +/- 2
Column “c”
0 +/- 2
Exposure “e”
100 +/- 20
Last Hand Read Score
Aux Out 2
Aux Out 1
* Aux Out 0
* Lock
Aux In 2
Request to Exit
Aux In 1
Door Monitor Switch
Tamper
* These status values are inactive if the
reader is in Card Reader Output Mode.
O = Circuit Open H = Output is OFF (High)
C = Circuit Closed L = Output is ON (Low)
O C O C O H L H L NN
- ENTER ID -
O C O C O H L H L NN
These Input/Output
values do not apply to
the HandPunch 50E
Содержание HandPunch 50E
Страница 1: ...HandPunch 50E Manual ...
Страница 10: ...Introduction Page 8 This page is intentionally blank ...
Страница 14: ...Planning an Installation Page 12 This page is intentionally blank ...
Страница 22: ...Wiring Connections Page 20 This page is intentionally blank ...
Страница 24: ...Ereasing Memory Page 22 This page is intentionally blank ...
Страница 26: ...Closing the HandPunch Page 24 This page is intentionally blank ...
Страница 30: ...Enter a Command Menu Page 28 This page is intentionally blank ...
Страница 50: ...Maintenance Page 48 This page is intentionally blank ...
Страница 56: ...Appendix B Troubleshooting Guide Page 54 This page is intentionally blank ...
Страница 58: ...Warranty Page 56 This page is intentionally left blank ...