Power supply
Connection of the I/O modules RM-V8 / RM-V16 to the controller types
RM-310 C / RM-310 CT
Digital inputs E1 ... E6, 24 V DC
Input
Factory-set function
E1
Release of the control when 1-signal is present
E2
The function is set with the parameter F2
E3
Acknowledge alarm
E4
Continuous cleaning with Interval 1
E5
Cleaning off (priority over Cleaning on)
E6
Cleaning release
The function of the inputs can be individ-
ually set via parameter group F0-F6. See
appendix 7 "Input and output signal par-
ametrisation, special parameter".
The prefabricated cables from RECO are
used to connect the RM-V6/X I / O modules
to the controller types RM 310 C Plug and
Play / RM 310 CT Plug and Play.