3
Wait at least 7 sec. to enter on setting mode ( warning!! If 7 seconds are not attended you will not enter on setting mode)
Hold on the seal switch 2 and press on start cycle switch 1 one time per each seconds of waiting time required ( more seconds = more vacuum)
Release the switch.
DEFAULT SETTING
To return to default setting:
Before connecting the plug to power supply, press and hold on Start cycle switch (1) and Seal switch ( 2 ) together;
Connect the plug to power supply;
Wait for at least 5 seconds;
Release the switch
QUESTIONS / ANSWERS
In case of doubts about the correct functioning of the appliance, some test can be done by then user to verify the performances of the machine.
Internal functioning:
1-
Open the cover and start the cycle once blocked the air suction plug Image 6
2-
If the manometer arrive on red ( or the red led light on ) and the seal start automatically, inside the machine all is good.
3-
If the manometer arrive on red ( or the red led light on ) but the seal do not start automatically, set the unit on automatic cycle and re-test
4-
If the manometer do not arrive on red ( or the red led do not light on ), the machine must be repaired
Cover and vacuum gasket functioning:
1-
Close the cover ( without bag) and press pump switch ( 1 ) to start the cycle, slightly press with both hands the cover. Image 7
2-
If the manometer arrive on red ( or the red led light on ) and the seal start automatically, the machine is good.
3-
If the manometer arrive on red ( or the red led light on ) but the seal do not start automatically, set the unit on automatic cycle and re-test
4-
If the manometer do not arrive on red ( or the red led do not light on ), pls check the vacuum chamber gasket, clean or replace and re-test
Bag test:
1-
Open the cover
2-
Place the open side of
an empty
vacuum bag in the vacuum chamber , between the gaskets . Image 1
3-
Close the cover and press pump switch ( 1 ). This will start vacuum operation.
4-
As soon as vacuum pump starting, slightly press with both hands the cover so as it sticks to the surface of the bag. After a few seconds the
depression created by the pump will permit to release the cover, while the machine will keep on suction
5-
If the manometer arrive on red ( or the red led light on ) and the seal start automatically, the machine is good.
6-
If the manometer arrive on red ( or the red led light on ) but the seal do not start automatically, set the unit on automatic cycle and re-test
With those 3 test you can check the correct functioning of the appliance and the correct placing of the bag in the vacuum chamber.
You can have a good vacuum only if there is enough empty free space between the food and the machine to avoid the creation of wrinkles and
folds can limit the vacuum reached inside the bag.
Without wrinkles and folds you can have a correct cover closing and the vacuum/seal cycle can be done without problems.
Automatic seal can only start if the vacuum level is correct.
Good seal can be done only if the cover press correctly the sealing bar and cover can press correctly only if a good vacuum level is reached.
The unit does not start:
1-
Check if the plug is well connected
The bag is not well sealed / Air come in the bag:
1-
In winter season, the sealing bar can be charged in humidity, at first use start a complete vacuum/seal cycle with cover closed and no bag.
To avoid problems, the unit must be stored in a dry and no dust place at +10°-+30°
2-
Bags are nylon external part, nylon is an hygroscopic material, to avoid seal problems due to humidity, store bags in a dry and no dust
place at +10°-+30°
3-
You can have a good vacuum only if there is enough empty free space between the food and the machine to avoid the creation of wrinkles
and folds can limit the vacuum reached inside the bag. Without wrinkles and folds you can have a correct cover closing and the
vacuum/seal cycle can be done without problems. Good seal can be done only if the cover press correctly the sealing bar and cover can
press correctly only if a good vacuum level is reached
4-
Check if the open part of the bag is clean; placing food inside the bag can leave some food residuals: the part of the bag must be sealed,
must be proper
5-
Check if the food which is to be vacuum preserved is free of every thorns or spikes could pierce the bag
6-
Humidity of the food can damage the seal: check if food is correctly dried or use a double bag. Place food in a first bag, bend repeatedly
the open part of the bag ( Image 8) and put the first bag in a second one with the upper part to the bottom of the second ( Images 9 and
10). You can have same vacuum but the humidity will remains in the first bag ( Image 11)
7-
Using rolls, the first seal must be done placing the open part of the roll on seal bar only avoiding to put in the vacuum chamber ( Image 2);
the appliance can correctly seal only if there is a correct vacuum level and the cover press correctly on the sealing bar
8-
Only seal cycle: Place the open part of the bag as per Image 2, on the sealing bar only and not in the vacuum chamber and make a
complete automatic vacuum/seal cycle to have a good seal.
9-
If the air comes into the bag in seal cycle, and after a correct vacuum cycle, the bag is damaged and must be changed.
No vacuum in the bag:
1-
Check the open part of the bag is correctly placed in the vacuum chamber and between the black gasket Image 1
2-
Use the test Internal functioning, Cover and gasket and bag test to be sure the appliance is good.
3-
Suction of liquids can damage the gasket of vacuum chamber reducing the vacuum possibility of the machine, check the gasket and change
if necessary.
4-
The appliance is prepared for use Reber embossed bags of the same type as furnished with the machine, if used with different or other label
bags the machine could not have same performances.
5-
In Summer period, when ambient temperature became high, or in case of continued and intensive use, the residual heat of the sealing bar
could pre-seal the bag and prevents vacuum. Use potentiometer or electronic setting to reduce seal power, wait some minutes and re-start