The Thalia board provides:
• One STOP command input
• One obstruction sensing device
input that reacts to the input
in both opening (stops) and
closing (reverses) cycles. This is
UL 325-2016 compatible with
it’s SAFE 1 with its mandatory
supervision circuit input FAULT
1. SAFE 1, 001 PHOT TEST
(default setting) and 005 PHOT
CL TEST reacts to input during
closing only
• Two programmable obstruction
sending devices input for SAFE
2 and SAFE 3, both are provid-
ed with optional supervision
circuit FAULT 2 and FAULT 3
SAFETY DEVICES
All 3 safety inputs are normally closed (N.C.) contacts. All the FAULT inputs
are normally open (N.O.) contacts.
TERMINAL
NAME
DESCRIPTION
DEFAULT
70
COM
Safety positive common
Common
71
STOP
Stop command
STOP
Overrides all other commands
72
SAFE 1
Safety input #1
PHOT
Stops operators during
opening, reverses on closing
73
FAULT 1
Supervisory circuit for SAFE 1
FAULT
Requires opposite relay state
from SAFE 1
74
SAFE 2
Safety input #2
006-BAR
Programmable input
75
FAULT 2
Supervisory circuit for SAFE 2
FAULT
Requires opposite relay state
from SAFE 2
76
COM
Safety positive common
Common
77
SAFE 3
Safety input #3
015-
SHADOW
Programmable input
78
FAULT 3
Supervisory circuit for SAFE 3
FAULT
Requires opposite relay state
from SAFE 3
17
PR
OGRAMMING FEA
TURES