SAFE 2 and SAFE 3 can be programmed to perform any of the following
instructions under the “LOGIC” sub-menu:
TERMINAL
NAME
DESCRIPTION
000
PHOT
System reacts to the input in both opening (stops) and closing
(reverses) cycles
001
PHOT TEST
Same as above. Requires the device to supervised (FAULT active)
002
PHOT
OP
System reacts to the input only during the opening cycle (stops)
003
PHOT OP TEST
Same as above. Requires the device to be supervised (FAULT active)
004
PHOT CL
System reacts to the input only during the closing cycle (reverses)
005
PHOTO CL
TEST
Same as above. Requires the device to be supervised (FAULT active)
006
BAR
Safety edge input. It reacts in both opening and closing. It stops and
partially reverses
007
BAR TEST
Same as above. Requires the device to be supervised (FAULT active)
008
BAR 8K2
Safety edge input with EOL resistor as supervision method. Only active
on SAFE 2
009
BAR OP
Safety edge input. During opening it stops and partially reverses.
During closing it stops
010
BAR OP TEST
Same as above. Requires device to be supervised (FAULT active)
011
BAR OP 8K2
Safety edge with EOL resistor as supervision method.
During opening it stops and partially reverses. During closing it stops.
Active only on SAFE 2
012
BAR CL
Safety edge input. During closing it stops and partially reverses.
During opening it stops.
013
BAR CL TEST
Same as above. Requires the device to be supervised (FAULT active)
014
BAR CL 8K2
Safety edge input with EOL resistor as supervision method. During
closing it stops and partially reverses. During closing it stops. Active
only on SAFE 2
015
SHADOW
Safety loop input. If the contact is closed, it prevents any movement of
the door leaves when the doors are open (Value 0 on the LOGIC
SHADOW) or when the doors are both open and closed (Value 1 of the
LOGIC SHADOW)
18 PR