• If wire is not to be run in the wall,
attach using the staples provided.
• If wire is not to be run in the wall,
attach using the staples provided.
• Strip insulation back on the ends of
the wire that are to be inserted into the
terminal inside the controller housing.
• Insert wires into terminal #’s 15 and
16 and tighten screws securely. Note:
polarity is not observed.
20
W
ALL
BUTT
ON INS
T
ALLA
TION
P R O G R A M M I N G W A L L B U T T O N
The wall button requires that the input command to be reprogrammed on
the control board to open and close the doors (please see page 13 on pro-
gramming menu for reference). If you do not program the control board
the wall button will only open the doors.
To change the default setting of OPEN to a START input please follow these
steps:
• On the control board please press [OK] twice quickly
• “HALT” will appear on the display
• Press [OK] twice again and “PARAM” will appear on the display
• Press the [–] button one time and the display show “LOGIC”
• Press the [OK] button, “TCA” will appear on the display
• Press the [-] button until you see “IC 1” and press [OK]
• Adjust the “IC 1” to value of 000