2.3 ELECTRICAL CONNECTIONS / COLLEGAMENTI ELETTRICI
Disconnect the ventilator from power mains prior to
any electric installation operations.
The ventilator maintenance and installation shall
only be performed by a professional electrician
qualified for unassisted operations on electrical
installations up to 1000 V after careful study of the
this user’s manual.
The rated electrical parameters of the unit are stated
on the rating label. Any tampering with the internal
connections is prohibited and will void the warranty.
The unit has been designed for connection to single-phase ac
1~100-230 V / 50-60 Hz power mains using a pre-wired cable and
a plug.
Connect the WHR 50 to power mains through the automatic circuit
breaker with magnetic trip integrated into the fixed wiring system.
Input
L
G
-
D
N
Output
L
G
-
D
N
Input
L
G
-
D
N
1~100-230 V
50-60 Hz
SINGLE HEAT RECOVERY UNIT
L’unità prevede il collegamento alla rete domestica monofase
1~100-230 V ac / 50-60 Hz con apposito cavo di alimentazione.
Prevedere un interruttore magnetotermico sulla linea di
alimentazione elettrica .
Scollegare il WHR 50 dalla rete elettrica prima di
effettuare qualsiasi operazione di installazione
elettrica.
La manutenzione e l'installazione del WHR 50
devono essere realizzate solamente da un elettricista
qualificato per lo svolgimento di operazioni senza
assistenza su installazioni elettriche fino a 1000 V
previo attento studio del presente manuale d'uso.
I parametri elettrici nominali dell'unità sono
indicati nella etichetta. Qualsiasi manomissione dei
collegamenti interni è vietata e annullerà la garanzia.
RECUPERATORE DI CALORE SINGOLO