43
ENGLISH
RS 485 SERIAL PORT PROTOCOL
This manual section concerns the RS 485 serial port protocol (
REM-CTRL
21
, usually
for RCF TS 9918 remote controls) that is necessary to develop a custom software (not
supplied by RCF) in case other remote controls (e.g. AMX® / CRESTON® type) shall be
used.
This protocol concerns both AX 8042 automixer and ZX 8060 (any difference is
indicated).
CONNECTION
-
Half-duplex RS-485, point-to-point.
-
No multi-slave addressing is considered, only one unit can be controlled.
-
8N1, 38400 baud.
PROTOCOL
A simple, ASCII control protocol is available, as follows:
-
AX 8042 / ZX 8060 only replies to commands, no spontaneous messages are sent.
-
This protocol is case sensitive.
-
A command is terminated by a CR (0x0D ASCII character).
-
AX 8042 / ZX 8060 always replies to a command with a response line, terminated by a
CR. The first field is the response code, if it applies, further fields will follow separated
by spaces.
-
Before sending a new command, it is mandatory to wait for the reply of the previous one.
If no reply is needed, ACK will be returned.
RESPONSE CODE
0
ACK (‘acknowledge’, proper data reception)
1
NACK (‘negative acknowledge’, no data reception)
2
BAD COMMAND
3
COMMAND OK, BAD PARAMETERS
4
PARAMETER OUT OF RANGE