28
ENGLISH
Slope
: filter slope setting (dB / oct).
Q
: Q factor setting.
Gain (dB)
: filter gain setting.
Freq (Hz)
: either filter frequency selection or PEQ central frequency setting.
File Commands:
-
SAVE
: it saves to PC the current equalization as .rde file.
-
LOAD
: it loads from PC an equalization previously saved as .rde file.
Eq. options:
-
FLATTEN
: it disables all filters (flat frequency response).
-
BYPASS EQ.
: it disables the equalization, but without changing filter settings.
-
PHASE PLOT
: if selected, the phase plot is shown (green line).
Devices commands:
-
STORE
: it sends and stores the equalization to AX 8042.
-
SEND
: it sends (without storing) the equalization to AX 8042.
For each filter, frequency and gain can be adjusted either graphically (through the mouse)
by dragging the little coloured square or in an analytical way (by inserting the values in
the cells or rotating the control).
The overall equalization is shown as a red line, the intervention of the selected filter as a
green line, the intervention of a filter that is not selected as a white line.
For example, to apply a 6 dB attenuation at 800 Hz through a parametric equalizer:
enable the filter 1 by clicking its ‘Enabled’ checkbox, select the PEQ filter type, set its
bandwidth (e.g. 2.0), its gain to –6 dB and frequency to 800 Hz.
Finally, click either STORE (send and store) or SEND (send without storing) to send all EQ
settings to AX 8042.