background image

 

LIF200 User Manual

 

31

 

 

c)

 

Configure your port settings as follows: 

i)

 

Set: Bits per second = 115200 

ii)

 

Set: Data bits = 8 

iii)

 

Set: Parity = None 

iv)

 

Set: Stop bits = 1 

v)

 

Set: Flow control = None 

 

Содержание LIF-200

Страница 1: ...LIF 200 RS232 RS485 to TCP IP Converter Module USER MANUAL ...

Страница 2: ... is subject to change at any time without notice This book is provided as is without warranty of any kind either express or implied including but not limited to performance merchantability or fitness for any particular purpose Neither RBH Access Technologies Inc nor its dealers distributors or affiliates shall be liable to any person or entity with respect to any liability loss or damage caused or...

Страница 3: ...TUP WITH DHCP CLIENT 8 3 3 ONE PAGE QUICK SETUP WITH PPPOE 9 3 4 CHANGE PASSWORD 10 3 4 1 Changing User Name and Password 10 4 LIF 200 ADVANCED CONFIGURATION SETUP 11 4 1 OPERATION MODE 11 4 2 SERIAL TYPE 14 5 LIF 200 MANAGEMENT SETUP 16 5 1 DEVICE ADMIN 16 5 2 DEVICE STATUS 18 5 3 BACKUP AND RESTORE 19 5 4 UPGRADE FIRMWARE 20 5 5 PING 21 6 TROUBLESHOOTING 22 APPENDIX A PRODUCT SPECIFICATIONS 23 A...

Страница 4: ...n select one of these types depending on your application requirements DHCP Client The DHCP Dynamic Host Configuration Protocol client obtains the TCP IP configuration at start up from a centralized DHCP server PPPoE Over Ethernet PPPoE is a protocol for connecting remote hosts to the Internet over a DSL connection by simulating a dial up connection Dynamic DNS With dynamic DNS support you can hav...

Страница 5: ...LIF200 User Manual 3 1 3 Applications for LIF 200 Figure 1 LIF 200 applications ...

Страница 6: ...minals beside the RS485 port or through the center positive modulat plug on the same side as the RJ45 jack 2 1 2 Communications The LAN communication is connected to the RJ45 jack and the serial communication can be connected through either the RS232 port DB9M or the RS485 port terminal block Ensure that both the programming and the slide switch are set the same RS232 or RS485 ...

Страница 7: ...e with a subnet mask of 255 255 255 0 This is necessary to ensure that your computer can communicate with your LIF 200 Your computer must have an Ethernet card and TCP IP installed TCP IP should already be installed on computer using Windows 98 2000 XP and later operating systems Note To connect a computer directly to the LIF 200 Ethernet port use a crossover Ethernet cable if both the computer an...

Страница 8: ...ree IP connection types Static IP DHCP and PPPoE These types are listed in the drop down menu for the IP Configuration setting Each setup screen and available features will differ depending on what kind of IP connection type you select The default setting is Static IP Check the software version of your IPLocator under Help About The default user is RBH and the default password is password 3 1 One ...

Страница 9: ... chose Others and enter your own value Operation Mode Connection Mode TCP Server Connection Port Number 3002 Remote Host IP Address Only used with TCP Client If you are connecting through a static or fixed IP address from your network perform these steps Step 1 Enter IP address Step 2 Enter Subnet mask Step 3 Enter Gateway IP address Step 4 Enter Primary DNS IP address Step 5 Select correct settin...

Страница 10: ...Server Connection Port Number 3002 Remote Host IP Address Only used with TCP Client If there is a DHCP Server existing in your network environment or you subscribe a CABLE service from your ISP you can set your IP configuration to DHCP to get a dynamic IP address The Host Name is an optional item depending on your DHCP Server setting Note 1 To use a CABLE service you also need to change the MAC ad...

Страница 11: ...ial Port Mode Serial Type RS232 Baud Rate 9600 If no suitable Baud Rate appears in the drop down menu chose Others and enter your own value Operation Mode Connection Mode TCP Server Connection Port Number 3002 Remote Host IP Address Only used with TCP Client If you subscribe to a DSL service with PPPoE connection from your ISP you can set the IP configuration to PPPoE to get a dynamic IP address Y...

Страница 12: ...n the PPPoE connection established each time you can select PPPoE with Fixed IP Address as ENABLE and enter the IP address given to you from your ISP 3 4 Change Password 3 4 1 Changing User Name and Password 1 On the left side of the screen under Management select Device Admin and open the Device Administration Setting screen 2 Beside Administrator Password type in a new user name and password ver...

Страница 13: ... passive to accept commands from a remote and data reception by the peer needs to be guaranteed then you can set the LIF 200 as TCP Server Be sure that the value Listen Port Number is set to the same value that your remote control application is using Close Connection When Remote Idle second default 100 range 0 to 32768 If you want to keep the connection between LIF 200 and your remote control app...

Страница 14: ... port it is sent out on a first in first out basis to the serial port TCP Client Remote Connection Port Number default 3002 range 0 to 65535 Remote Host IP Address default 0 0 0 0 If your device is configured as active to report real time status to a remote and data reception by the peer needs to be guaranteed then you can set the LIF 200 as TCP Client Be sure the value Remote Connection Port Numb...

Страница 15: ... If your device is configured as passive to accept commands from a remote and data reception by the peer needn t be guaranteed then you can set the LIF 200 as UDP Server Be sure the value Listen Port Number is set to the same value that your remote control application is using UDP Client ...

Страница 16: ... are listed in the drop down menu for the Serial Type setting Each setup screen and available features will differ depending on what Serial Type you selected The default setting is RS232 RS232 RS485 Baud Rate default 9600 range 1200bps to 230 4Kbps Others If no suitable Baud Rate appears in the drop down menu chose Others and enter your own value Data Bits 5 6 7 8 default Parity Check None default...

Страница 17: ...acket Transmit Length bytes default 0 range 0 to 65535 You can fix the length of a transmitted Ethernet packet Tune this setting value to fit the data length of the packet to match your device RS485 Only RS485 Transmission Delay Time ms default 0 range 0 to 65535 Different devices have different capabilities for handling data received from a serial port For this reason you can tune this setting to...

Страница 18: ...2 168 168 125 8080 in your browser Device Management IP Address default 192 168 200 200 In case the LIF 200 s IP address is forgotten you can use this management IP to connect to LIF 200 in order to figure out what the current IP address is If you set the LIF 200 s IP Configuration as DHCP or PPPoE which will assign dynamic IP address to LIF 200 you also can use this management IP address to find ...

Страница 19: ...irm it Block Ping Request default UNBLOCK To prevent hacker intruding your network check the BLOCK option to enable this function to reject the PING requests from Internet MAC Address Change The LIF 200 s MAC address can be changed from the original values if necessary Some ISPs require users to change the MAC address to a registered one when users change their access equipment Detail sees Appendi...

Страница 20: ...are System up Time the time of system from start up to current Management IP Address the current setting of management IP Ethernet Status the LIF 200 s IP Configuration MAC address IP address subnet mask default gateway IP address primary DNS IP address and current connection status Serial Status the LIF 200 s setting in serial type Statistic the transmission and receive bytes and packets count in...

Страница 21: ...e you previously saved to turn the settings back Backup Click Backup button save the current configuration as a backup file in your hard disk Restore Enter path of the configuration file you saved on the PC You can click Browse to view the folders and select the file Click Restore to retrieve it Note the sub name of file you retrieve must be cfg ...

Страница 22: ...file to upgrade you have to enter path of the latest firmware you saved on the PC You can choose Browse to view the folders and select the firmware Upgrade After you have entered or selected the path click Upgrade to start the firmware upgrade process Note don t power off the router during the firmware upgrading otherwise the incompletion of firmware upgrading will cause serious damage to the inte...

Страница 23: ... Only Destination IP Address the IP Address of destination device you want to ping Packet Number the packet numbers you wish to use to ping the destination device The maximum numbers are 4 Packet Size the numbers of packet size you wish to use to ping the destination device The maximum packet sizes are 60 Ping Result The result will show the numbers of sending packet numbers of packet receiving Re...

Страница 24: ...ck cable connection between LIF 200 and computer or hub Ping LIF 200 from computer Make sure your computer Ethernet card is installed and functioning properly Can not ping any computer on the LAN If the 10 100M LED is off check the cable connection between LIF 200 and your computer Verify that the IP address and subnet mask of the LIF 200 and computer are in the same IP address range Can not acces...

Страница 25: ...erformance Speed 50 bps 230 Kbps Configuration Parity None even odd Mark Space Data bits 5 6 7 8 Stop bits 1 2 with parity setting of None OS Support Windows 98 2000 XP Protocol TCP IP UDP Telnet RTelnet DHCP ICMP Management Serial console Telnet console Windows Utility IP Search program Firmware Upgrade by web Power and Environment Power requirements DC 9V 300 mA max DC 12V 230 mA max DC 24V 160 ...

Страница 26: ...rior to the Web as a generic term for user interfaces that let you browse text files online Cable Modem A device that connects a computer to the cable television network which in turn connects to the Internet Once connected cable modem users have a continuous connection to the Internet Cable modems feature asymmetric transfer rates around 36 Mbps downstream from the Internet to the computer and fr...

Страница 27: ...achine Without DHCP the IP address must be entered manually at each computer and if computers move to another location in another part of the network a new IP address must be entered DHCP lets a network administrator supervise and distribute IP addresses from a central point and automatically sends a new IP address when a computer is plugged into a different place in the network DHCP uses the conc...

Страница 28: ...ansmission IP Address In the most widely installed level of the Internet Protocol IP today an IP address is a 32 binary digital number that identifies each sender or receiver of information that is sent in packets across the Internet When you request an HTML page or send e mail the Internet Protocol part of TCP IP includes your IP address in the message actually in each of the packets if more than...

Страница 29: ...re residing on a modem or router Subnet Mask The method used for splitting IP networks into a series of subgroups or subnets The mask is a binary pattern that is matched up with the IP address to turn part of the host ID address field into a field for subnets TCP Transmission Control Protocol A method protocol used along with the IP Internet Protocol to send data in the form of message units datag...

Страница 30: ...dix to find the adapter s MAC or IP address in Windows 98 Me 2000 or XP 1 Click Start and Run In the Open field enter cmd Press the Enter key or click the OK button 2 At the command prompt enter ipconfig all Then press the Enter key 3 Write down the Physical Address as shown on your computer screen Figure D 1 it is the MAC address for your Ethernet adapter This appears as a series of numbers and l...

Страница 31: ...0 t o f a c t o r y d e f a u l t Set LIF 200 to factory default with push button 1 Power off LIF 200 2 Click hold the Reset Button 3 Power on LIF 200 4 Release the Reset Button after about 3 seconds 5 The LIF 200 is now reset to the factory default settings ...

Страница 32: ...must use a crossover cable The second pin of the LIF 200 connects to the third pin of the computer and the third pin of the LIF 200 connects to the second pin of the computer 2 Run HyperTerminal a Enter a name and select an icon for this communication then click OK to continue b Select the appropriate COM port for the LIF 200 connection to the computer then click OK to continue ...

Страница 33: ...LIF200 User Manual 31 c Configure your port settings as follows i Set Bits per second 115200 ii Set Data bits 8 iii Set Parity None iv Set Stop bits 1 v Set Flow control None ...

Страница 34: ... confirm port settings 3 With HyperTerminal set as the working window repower the LIF 200 and click Ctrl R within three seconds of the LIF 200 being powered on 4 Use IP Locator to confirm that the factory default settings have been reset ...

Отзывы: