Hierarchy of Photocell vs. Telemetry
The telemetry function enables the choice of wavelength. The photocell must detect
that it is dark for the telemetry function to operate.
The photocell overrides the telemetry function during the day. If the external
input/telemetry function needs to be operated 24 / 7, then the photocell function should
be disabled from the settings / groups page.
If the external input/telemetry is not active, then the unit will follow the photocell settings.
The system requires 15 seconds of light to deactivate the photocell and turn the
illuminators off to avoid accidental turn off of the illuminators via car headlights or torches.
If illuminators are in groups, the following rules apply:
-
ANY sending illuminator within a group which says it is dark will turn all the illuminators
in the group on (subject to local illuminator settings)
-
ALL illuminators in the group need to say it is light before all the group illuminators will
go off together (subject to local conditions)
Log-in, Security & Basic Illuminator Setup
Log-in using Operator or Administrator user names and passwords. Operator has limited
access rights. Administrator has full access rights.
Defaults (User Names & Passwords are case sensitive):
Users & Passwords
Name
Password
Operator
user
password
Administrator
admin
password
In order to maintain maximum security of your system, we recommend you change the
passwords at the earliest opportunity (for further information, please see GUI Access page and
“Access / Passwords Section” of full installation instructions).
Take instant control of a illuminator by pressing the Override button on the home page. This will
countdown for 30 minutes to allow the user to control the illuminator and then will revert to
standard settings automatically or if the Override button is deselected. Override is only
available when the illuminator mode is set to
Local,
HTTP + Local
or
VMS + Local
.
To operate the illuminator via a VMS or third party application that uses the Raytec API, then the
illuminator mode should be set to
VMS
or
VMS + Local.
In VMS mode the illuminator will ignore
Photocell and External Input triggers and respond only to valid VMS commands. In
VMS +
Local
mode the illuminators can be controlled via a VMS system whilst also still responding to
local photocell and telemetry triggers.
To operate the illuminator with an application that uses the HTTP API, then the illuminator mode
should be set to
HTTP
or
HTTP + Local.
In HTTP mode the illuminator will ignore Photocell and
External Input triggers and respond only to valid HTTP commands. In
HTTP + Local
mode the
illuminators can be controlled with HTTP commands whilst also still responding to local
photocell and telemetry triggers.