(Quick Installation Guide P1-19/ Detailed Guide – see Raytec website) 

STEP 1:

 Safety 

Information (Pg. 2) 

 

STEP 2:

 Wiring (Pg. 7) 

For PoE, use standard CAT 5 or better for both power and data. For all 8 sized products, check 

the PoE detection resistance of the illuminator is compatible with your PoE equipment (24.9K

 

is factory default).  

  

For  low  voltage  (non-PoE)  apply  24V  DC  to  red  and  black  cores  of  auxiliary  cable  and  use 

standard  CAT  5  or  better  for  data  connection.  Connect  external  inputs  and  external  output 

wires as required. 
 
IMPORTANT: 

To choose between Infra-Red and White Light configure using the GUI interface  
Default is IR for P/cell senses darkness and WL for Ext. Input if active when P/Cell senses darkness. 
Ensure PoE equipment or 24V PSU are suitably rated 
For 8 sized products check PoE detection resistance is set correctly 
Ensure Cat 5 cable and auxiliary cable are correctly terminated and waterproofed after installation 
If using low voltage, a CAT 5 cable must still be connected to the network for communication 
If not using auxiliary cable, it must still be suitably terminated and waterproofed 

 

STEP 3: 

Physical Installation (Pg. 9-10) 

Adjust interchangeable lens if required.  

Fix to wall, pole or camera unit using U bracket provided or other Raytec bracketry.  

 
IMPORTANT:   

Ensure illuminator is rated to provide required viewing distances and select correct angle 
Ensure illuminator is orientated in the correct direction 

 

Содержание vario2ip HYBRID

Страница 1: ...gle IHD 60 x 25 beam angle IHD Waterproof RJ45 connector Accessories optional 80 x 30 beam angle IHD 120 x 50 beam angle IHD System requirements PC running Windows 7 with IE9 or equivalent and network...

Страница 2: ...se appropriate shielding eye protection Risk Group 2 for cornea lens infrared hazard Hazard distance is 2000mm Eye Safety White Light Caution EN62471 Risk Group 2 Classification Possible hazardous opt...

Страница 3: ...if low voltage 24V DC operation is preferred The Vario2 IPPOE Hybrid comes with a number of feratures that allow the user to change between the two wavelengths The illuminator has a photocell for auto...

Страница 4: ...TTL ve purple TTL GND External Output volt free yellow white CAT 5 Cable for Data and Optional PoE Interchangeable Lensing PoE Detection Resistance Selection Switch Please note base plate has been re...

Страница 5: ...Default is IR for P cell senses darkness and WL for Ext Input if active when P Cell senses darkness Ensure PoE equipment or 24V PSU are suitably rated For 8 sized products check PoE detection resistan...

Страница 6: ...P address can be altered or DHCP enabled Alternatively type the IP address of illuminator into a web browser default is 192 168 2 80 and use the web interface to manually alter IP address IMPORTANT We...

Страница 7: ...ithout boosting the signal Ensure you make a waterproof connection to the RJ45 as shown below Ensure the connector is waterproof and sealed after the connection is made To illuminator RJ45 RJ45 connec...

Страница 8: ...rn the power to the illuminator OFF remove the baseplate and access the switch as shown The majority of PSE equipment requires a detection resistance of 24 9K to establish a PoE link Some models of PS...

Страница 9: ...angle To alter to any other angle remove the existing lens and insert the required lens which will have its angle indicated on it Ensure the baseplate is securely re attached to maintain waterproof i...

Страница 10: ...pole using U bracket provided or dedicated Raytec bracketry Notes Unit can alternatively be powered by 24V DC if required Multi core auxiliary cable also fitted to unit Use for alternative power 24V...

Страница 11: ...ould now appear with a valid IP address You can now double click illuminator to navigate to it WARNING Your network must have DHCP capability Manually set the IP address Run Raytec Discovery Tool Sing...

Страница 12: ...etwork press Discover and the Raytec Discovery Tool will display a list of illuminators available on the network See instructions above on how to change IP address or enable DHCP in order to allow com...

Страница 13: ...d Operator user password Administrator admin password In order to maintain maximum security of your system we recommend you change the passwords at the earliest opportunity for further information ple...

Страница 14: ...photocell The External Input will activate the illuminator at 100 NOT soft start for the duration of the input provided the photocell detects it is dark External Output activated by photocell and wil...

Страница 15: ...l Output Type of Input Volt Free Trigger State Photocell Only Active State Short Circuit Low Active State Short Circuit Low Photocell Photocell Sensitivity 20 lux Basic Web Page Functionality All web...

Страница 16: ...16 User has access to Home Page and Diagnostics pages Administrator has access to all pages...

Страница 17: ...rol of illuminator either locally by VMS or HTTP commands Adv Settings Allows for further detailed setup of External Input External Output Photocell sensitivity level and duration of Override Access C...

Страница 18: ...rs below Chrome Internet Explorer 1 Hold Ctrl Shift Del keys 2 Change drop down box to the beginning of time 3 Tick Cached images and files ONLY If others are ticked untick 4 Select Clear browsing dat...

Страница 19: ...page 6 for required ratings Check connection and wiring of CAT5 6 cable to VARIO2 IPPOE HYBRID Verify link has been established with the router switch to which the illuminator is connected and that t...